首页> 外文期刊>Optik: Zeitschrift fur Licht- und Elektronenoptik: = Journal for Light-and Electronoptic >A Monte Carlo simulation study for feasibility of total variation (TV) noise reduction technique using digital mouse whole body (MOBY) phantom image
【24h】

A Monte Carlo simulation study for feasibility of total variation (TV) noise reduction technique using digital mouse whole body (MOBY) phantom image

机译:蒙特卡罗仿真研究,用于使用数字鼠标全身(MOBY)幻像图像的总变化(电视)降噪技术的可行性

获取原文
获取原文并翻译 | 示例
           

摘要

Although radiation dose based on X-ray source is becoming a concern, use of micro computed tomography (m-CT) system continues to grow in diagnostic imaging. To address radiation dose concern in m-CT system, Monte Carlo simulation using Geant4 Application for Tomography Emission (GATE) tool and noise reduction technique have recently developed. Among these techniques, total variation (TV) noise reduction technique is well known to many researchers for X-ray imaging. Also, an important disadvantage of median filter and Wiener filter is low edge preservation compared with recently developed noise reduction methods Thus, the aim of this study was to design TV noise reduction technique based on L1-norm estimation with iterative method and compare to other techniques in m-CT system using GATE simulation. We used 4-dimension (4D) digital mouse whole body (MOBY) phantom and to clarify the feasibility of TV noise reduction technique in m-CT images, we compared the image performance using contrast-to-noise ratio (CNR) and coefficient of variation (COV). According to the results, the average for three image planes (coronal, sagittal and transverse) of CNR and COV of the TV noise reduction technique were 68.07 and 1.61%, respectively. In particular, the CNR and the COV difference between TV noise reduction technique and noisy image were maximum 5.28 and 2.89 times, respectively. In conclusion, the results of this study suggested that TV noise reduction technique can be achieved improved performance and the effect and feasibility of TV noise reduction technique for m-CT imaging can be investigated. (C) 2017 Elsevier GmbH. All rights reserved.
机译:虽然基于X射线源的辐射剂量是日益关注的问题,使用微计算机断层扫描(M-CT)系统继续在诊断成像中生长。在M-CT系统地址辐射剂量的关注,使用用于发射体层摄影术应用GEANT4(GATE)工具和噪声降低技术蒙特卡罗模拟最近开发。在这些技术中,总变化(TV)噪声降低技术是公知的许多研究人员的X射线成像。此外,中值滤波器和维纳滤波器的一个重要缺点是用最近开发的噪声降低方法因此相比低边缘保持,本研究的目的是设计基于与迭代方法L1范数估计电视噪声降低技术,并比较其它技术以m-CT系统中使用模拟GATE。我们使用4维(4D)数字小鼠全身(MOBY)幻象,并澄清电视降噪技术在M-CT图像的可行性,我们比较了使用对比噪声比(CNR)和系数的图像性能变化(COV)。根据研究结果,平均为电视降噪技术的CNR和COV的三个图像平面(冠状,矢状和横向)分别为68.07和1.61%之间。特别地,CNR和电视噪声降低技术和噪声图像之间的差COV为最大5.28 2.89倍。总之,本研究的结果表明,可以实现的是电视噪声降低技术改进的性能和电视降噪技术的对于m-CT成像可以进行调查的效果和可行性。 (c)2017年Elsevier GmbH。版权所有。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号