...
首页> 外文期刊>Current medical research and opinion >Epidural block with ropivacaine and bupivacaine for elective caesarean section: maternal cardiovascular parameters, comfort and neonatal well-being.
【24h】

Epidural block with ropivacaine and bupivacaine for elective caesarean section: maternal cardiovascular parameters, comfort and neonatal well-being.

机译:罗哌卡因和布比卡因硬膜外阻滞用于选择性剖腹产:孕妇心血管参数,舒适度和新生儿健康。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

OBJECTIVE: To determine cardiovascular effects and neonatal outcome of ropivacaine 0.75% and bupivacaine 0.5% for elective epidural caesarean section. RESEARCH DESIGN AND METHODS: Healthy pregnant women, scheduled for elective caesarean section, were enrolled in this randomised, double-blind study. Epidural block was obtained with 20-30 ml of ropivacaine 0.75% (Group R) or bupivacaine 0.5% (Group B) and surgery did not commence until anaesthesia was achieved bilaterally to T6. MAIN OUTCOME MEASURES: Maternal heart rate and blood pressure were assessed before the main dose of local anaesthetic and at 5-min intervals until 35 min. Neonatal umbilical pH and Apgar scores were determined after delivery. Ten, twenty and thirty minutes after the main dose, sensory and motor block characteristics were determined. Quality of analgesia was assessed by the anaesthetist, surgeon and the patient. Adverse events were recorded. RESULTS: Sixty-two patients were enrolled and the data of 60 of them were eligible for analysis: 31 in Group R and 29 in Group B. The area under the curve (AUC) for maternal heart rate decreased significantly less in Group B than in Group R (p = 0.038). Twenty-five and thirty minutes after administration of the main local anaesthetic dose, heart rate decreased significantly less in Group B than in Group R (p = 0.006 and p = 0.007). There was no difference in AUC for maternal blood pressure (p = 0.32). Repeated measurement analysis showed no difference between groups in motor block (p = 0.78) and in spread of the sensory block (lower level: p = 0.83, upper level: p = 0.88). There was no statistical difference in neonatal umbilical pH (p = 0.22) and Apgar score (p = 0.59). Multiple linear regression analysis showed a significant influence of maternal body mass index on neonatal pH (p = 0.004), but not of maternal blood pressure (p = 0.323), nor of maternal heart rate (p = 0.12). The quality of analgesia and incidence of adverse events were similar in both groups. CONCLUSIONS: Both drugs produced equally satisfactory epidural block. Although ropivacaine 0.75% resulted in a greater decrease of maternal heart rate, this effect did not influence neonatal well-being. Both ropivacaine 0.75% and bupivacaine 0.5% can therefore be recommended for epidural anaesthesia in elective caesarean section.
机译:目的:确定选择性硬膜外剖宫产术中0.75%罗哌卡因和0.5%布比卡因对心血管的影响和新生儿结局。研究设计和方法:计划进行剖腹产的健康孕妇参加了这项随机,双盲研究。用20-30 ml 0.75%的罗哌卡因(R组)或0.5%的布比卡因(B组)获得硬膜外阻滞,直到开始双侧麻醉至T6才开始手术。主要观察指标:在进行局部麻醉之前,以5分钟为间隔,直到35分钟,评估孕妇的心率和血压。分娩后测定新生儿脐带pH和Apgar评分。主剂量后十,二十和三十分钟,确定感觉和运动阻滞特征。由麻醉师,外科医生和患者评估镇痛的质量。记录不良事件。结果:62例患者入选,其中60例数据符合分析条件:R组31例,B组29例。孕产妇心率曲线下面积(AUC)下降明显低于B例。组R(p = 0.038)。给予主要局部麻醉剂量后第二十五和三十分钟,B组的心率下降明显少于R组(p = 0.006和p = 0.007)。产妇血压的AUC没有差异(p = 0.32)。重复的测量分析显示,运动阻滞组之间的差异(p = 0.78)和感觉阻滞的分布范围无差异(较低水平:p = 0.83,较高水平:p = 0.88)。新生儿脐带pH(p = 0.22)和Apgar评分(p = 0.59)没有统计学差异。多元线性回归分析显示,母亲体重指数对新生儿pH有显着影响(p = 0.004),但对母亲血压(p = 0.323)和对母亲心率(p = 0.12)均无显着影响。两组的镇痛质量和不良事件发生率相似。结论:两种药物均产生同样令人满意的硬膜外阻滞。尽管罗哌卡因0.75%导致母亲心率下降更大,但这种影响并未影响新生儿的健康。因此,建议行选择性剖宫产术中的硬膜外麻醉建议使用罗非卡因0.75%和布比卡因0.5%。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号