首页> 外文期刊>Nanotechnology >Origin of noise in liquid-gated Si nanowire troponin biosensors
【24h】

Origin of noise in liquid-gated Si nanowire troponin biosensors

机译:液门Si纳米线肌钙蛋白生物传感器噪声起源

获取原文
获取原文并翻译 | 示例

摘要

Liquid-gated Si nanowire field-effect transistor (FET) biosensors are fabricated using a complementary metal-oxide-semiconductor-compatible top-down approach. The transport and noise properties of the devices reflect the high performance of the FET structures, which allows label-free detection of cardiac troponin I (cTnI) molecules. Moreover, after removing the troponin antigens the structures demonstrate the same characteristics as before cTnI detection, indicating the reusable operation of biosensors. Our results show that the additional noise is related to the troponin molecules and has characteristics which considerably differ from those usually recorded for conventional FETs without target molecules. We describe the origin of the noise and suggest that noise spectroscopy represents a powerful tool for understanding molecular dynamic processes in nanoscale FET-based biosensors.
机译:使用互补金属氧化物 - 半导体兼容的自上而下方法制造液门式Si纳米线效应晶体管(FET)生物传感器。 器件的运输和噪声特性反映了FET结构的高性能,这允许无标记检测心肌肌钙蛋白I(CTNI)分子。 此外,除了去除肌钙蛋白抗原之后,结构表明了与CTNI检测之前相同的特征,表明生物传感器的可重复使用操作。 我们的结果表明,额外的噪声与肌钙蛋白分子有关,具有与常规FET的那些具有显着不同的特征,没有靶分子。 我们描述了噪声的起源,并表明噪声光谱代表了理解基于纳米级FET的生物传感器中的分子动态过程的强大工具。