SU‐C‐209‐07: Phantoms for Digital Breast Tomosynthesis Imaging System Evaluation

机译:SU-C-209-07:用于数字乳房的幻影,用于数字乳房断层合成成像系统评估

获取原文
获取原文并翻译 | 示例
       

摘要

Purpose: Digital Breast Tomosynthesis (DBT) is gaining importance in breast imaging. There is a need for phantoms that can be used for image evaluation and comparison. Existing commercially available phantoms for DBT are expensive and may lack clinically relevant test objects. The purpose of this study is to develop phantoms for DBT evaluation. Methods Four phantoms have been designed and constructed to assess the image quality (IQ) of two DBT systems. The first contains a spiral of 0.3 mm SiC beads in gelatin to measure the tomographic slice thickness profile and uniformity of coverage in a series of tomographic planes. The second contains simulated tumors inclined with respect to the phantom base to assess tomographic image quality. The third has a tilted array of discs with varying contrast and diameter. This phantom was imaged alone and in a stack of TE slabs giving 2 to 10 cm thickness. The fourth has a dual wedge of glandular and adipose simulating materials. One wedge contains discs with varying diameter and thickness; the other supports a mass with six simulated spicules of varying size and a cluster of simulated calcifications. The simulated glandular tissue material varies between 35 and 100% of the total thickness (5.5 cm). Results: All phantoms were scanned successfully. The best IQ comparison was achieved with the dual wedge phantom as demonstrated by the spiculated mass and calcifications. Images were evaluated by two radiologists and one physicist. The projection images and corresponding set of tomographic planes were comparable and the synthesized projection images were inferior to the projection images for both systems. Conclusion: Four phantoms were designed, constructed and imaged on two DBT systems. They successfully demonstrated performance differences between two systems, and between true and synthesized projection images. Future work will incorporate these designs into a single phantom.
机译:目的:数字乳房Tomos合成(DBT)在乳房成像中获得重要性。需要对图像评估和比较的幽灵。 DBT的现有市售幻像是昂贵的并且可能缺乏临床相关的测试对象。本研究的目的是开发用于DBT评估的幻影。方法设计并构建了四种幽灵,以评估两个DBT系统的图像质量(IQ)。首先在明胶中含有0.3mm SiC珠粒的螺旋,以测量断层切断片厚度和一系列断层平面中的覆盖均匀性。第二个含有相对于幻象基础倾向于评估断层图像质量的模拟肿瘤。第三个具有倾斜的盘阵列,其具有不同的对比度和直径。该幻影单独成像,并在堆叠的堆叠中造成2至10cm的厚度。第四个具有腺体和脂肪模拟材料的双楔形物。一条楔子包含直径和厚度不同的圆盘;另一个支持具有六种不同尺寸的模拟斑块的质量和模拟钙化集群。模拟的腺体组织材料在总厚度(5.5cm)的35%和100%之间。结果:所有幻像都成功扫描。通过分子质量和钙化所证明的双楔形幻像实现了最佳的IQ比较。图像由两个放射科医师和一个物理学家评估。投影图像和对应的一组断层平面是可比较的,并且合成的投影图像差不等于两个系统的投影图像。结论:在两个DBT系统上设计了四个幽灵,构建和成像。他们成功地证明了两个系统之间的性能差异,以及真实和合成的投影图像之间的性能差异。未来的工作将将这些设计纳入一个幻影。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号