SU‐F‐E‐18: Training Monthly QA of Medical Accelerators: Illustrated Instructions for Self‐Learning

机译:SU-F-E-18:医疗加速器培训月度QA:自学说明

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

Purpose: To develop and test clear illustrated instructions for training of monthly mechanical QA of medical linear accelerators. Methods: Illustrated instructions were created for monthly mechanical QA with tolerance tabulated, and underwent several steps of review and refinement. Testers with zero QA experience were then recruited from our radiotherapy department (1 student, 2 computational scientists and 8 dosimetrists). The following parameters were progressively de‐calibrated on a Varian C‐series linac: Group A = gantry angle, ceiling laser position, X1 jaw position, couch longitudinal position, physical graticule position (5 testers); Group B = Group A + wall laser position, couch lateral and vertical position, collimator angle (3 testers); Group C = Group B + couch angle, wall laser angle, and optical distance indicator (3 testers). Testers were taught how to use the linac, and then used the instructions to try to identify these errors. A physicist observed each session, giving support on machine operation, as necessary. The instructions were further tested with groups of therapists, graduate students and physics residents at multiple institutions. We have also changed the language of the instructions to simulate using the instructions with non‐English speakers. Results: Testers were able to follow the instructions. They determined gantry, collimator and couch angle errors within 0.4, 0.3, and 0.9degrees of the actual changed values, respectively. Laser positions were determined within 1mm, and jaw positions within 2mm. Couch position errors were determined within 2 and 3mm for lateral/longitudinal and vertical errors, respectively. Accessory positioning errors were determined within 1mm. ODI errors were determined within 2mm when comparing with distance sticks, and 6mm when using blocks, indicating that distance sticks should be the preferred approach for inexperienced staff. Conclusion: Inexperienced users were able to follow these instructions, and catch errors within the criteria suggested by AAPM TG142 for linacs used for IMRT.
机译:目的:开发和测试明确说明的医疗线性加速器每月机械QA的培训说明。方法:为每月机械QA创建说明的说明,具有公差,并进行了几个审查和改进步骤。然后从我们的放射治疗部门(1名学生,2个计算科学家和8名Dosimetrys)招募了ZAA经验的测试人员。在Varian C系列LINAC上逐渐校准以下参数:A组A =龙门角角,天花板激光位置,X1钳位位置,沙发纵向位置,物理刻度位置(5个测试仪); B组= A组A +墙体激光位置,沙发横向和垂直位置,准直角度(3个测试仪);组C = B组+沙发角度,壁激光角和光学距离指示器(3个测试仪)。测试人员被教授如何使用LINAC,然后使用说明来尝试识别这些错误。根据需要,物理学家观察每个会议,支持机器操作。在多个机构的治疗师,研究生和物理居民组进一步测试了这些指示。我们还改变了使用非英语扬声器的说明模拟说明的语言。结果:测试人员能够按照说明进行操作。它们分别确定的龙门,准直器和沙发角度误差分别在0.4,0.3和0.9℃的实际改变值之内。激光位置在1mm内确定,在2mm内的钳口位置。横向/纵向和垂直误差分别在2至3毫米内测定沙发位置误差。附件定位误差在1mm内确定。在与距离棒的比较时,在2mm内测定ODI误差,并且使用块时6mm,表明距离棒应该是未经经验的工作人员的首选方法。结论:缺乏经验的用户能够遵循这些指示,并在AAPM TG142建议的标准中捕获用于IMRT的LINAC的标准。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号