AbstractA fast and reliable method was developed for simultaneous trace determination of nine odorous '/> Fast trace determination of nine odorant and estrogenic chloro- and bromo-phenolic compounds in real water samples through automated solid-phase extraction coupled with liquid chromatography tandem mass spectrometry
首页> 外文期刊>Environmental Science and Pollution Research >Fast trace determination of nine odorant and estrogenic chloro- and bromo-phenolic compounds in real water samples through automated solid-phase extraction coupled with liquid chromatography tandem mass spectrometry
【24h】

Fast trace determination of nine odorant and estrogenic chloro- and bromo-phenolic compounds in real water samples through automated solid-phase extraction coupled with liquid chromatography tandem mass spectrometry

机译:通过自动固相萃取与液相色谱串联质谱法相结合的实际水样中的九种气味和雌激素氯和溴 - 酚类化合物的快速测定

获取原文
获取原文并翻译 | 示例
           

摘要

AbstractA fast and reliable method was developed for simultaneous trace determination of nine odorous and estrogenic chloro- and bromo-phenolic compounds (CPs and BPs) in water samples using solid-phase extraction (SPE) coupled with liquid chromatography tandem mass spectrometry (LC-MS/MS). For sample preparation, the extraction efficiencies of two widely applied cartridges Oasis HLB and Sep-Pak C18 were compared, and the Oasis HLB cartridge showed much better extraction performance; pH of water sample also plays important role on extraction, and pH?=?2–3 was found to be most appropriate. For separation of the target compounds, small addition of ammonium hydroxide can obviously improve the detection sensitivity, and the optimized addition concentration was determined as 0.2%. The developed efficient method was validated and showed excellent linearity (R2?>?0.995), low limit of detection (LOD, 1.9–6.2?ng/L), and good recovery efficiencies of 57–95% in surface and tap water with low relative standard deviation (RSD, 1.3–17.4%). The developed method was finally applied to one tap and one surface water samples and most of these nine targets were detected, but all of them were below their odor thresholds, and their estrogen equivalent (EEQ) were also very low.]]>
机译: R <上标> 2 ?>?0.995),检测下限(LOD,1.9-6.2?NG / L),表面的良好恢复效率为57-95%,采用低相对标准偏差的自来水(RSD,1.3-17.4%)。最终施加开发的方法,对一个龙头,一个地表水样和大部分九个靶标被检测到,但所有这些靶向物质均低于它们的气味阈值,它们的雌激素当量(EEQ)也非常低。 < /摘要>]]>

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有