首页> 外文期刊>Environmental Science and Pollution Research >Long-term performance of vertical-flow and horizontal-flow constructed wetlands as affected by season, N load, and operating stage for treating nitrogen from domestic sewage
【24h】

Long-term performance of vertical-flow and horizontal-flow constructed wetlands as affected by season, N load, and operating stage for treating nitrogen from domestic sewage

机译:垂直流动和水平流动的长期性能构建湿地受季节,N负载和操作阶段,用于治疗国内污水的氮气

获取原文
获取原文并翻译 | 示例
           

摘要

To investigate the long-term nitrogen treatment efficiency in vertical-flow (VF)-horizontal-flow (HF) hybrid constructed wetlands (CWs), the nitrogen removal efficiency under different seasons, N loads, and three operating stages (representing age of the wetland) were evaluated over a 12-year period. The average total nitrogen (TN) removal efficiencies in the effluent during the operation period were in the following order: summer (75.2 %) > spring (73.4 %) a parts per thousand'aEuro parts per thousand autumn (72.6 %) > winter (66.4 %). The removal efficiencies of TN in summer, autumn, and spring were generally higher than those in winter. At different stages of operation (years), the average TN removal rates in the effluent were in the following order: middle stage (73.4 %; years 2006-2009) > last stage (72.0 %; years 2010-2013) > beginning stage (70.1 %; years 2002-2005). In VF-HF CWs, the amount of average TN removal (mg N m(-2) day(-1)) over the 12-year period was in the order of summer (5.5) a parts per thousand'aEuro parts per thousand autumn (5.1) > spring (4.3) a parts per thousand'aEuro parts per thousand winter (4.2) for the VF bed and in the order of summer (3.5) a parts per thousand'aEuro parts per thousand spring (3.5) a parts per thousand'aEuro parts per thousand autumn (3.3) > winter (2.7) for the HF bed, showing that the amount of TN removal per unit area (m(2)) in summer was slightly greater than that in other seasons. The amount of TN removal in the VF bed was slightly greater than that in the HF bed. Using three-dimensional simulation graphs, the maximum TN removal rate was at inflow N loads below 2.7 g m(-2) day(-1) in the summer season, whereas the minimum TN removal rate was at inflow N loads below 1.4 g m(-2) day(-1) in the winter season. Consequently, the TN removal efficiency was very stable over the 12 years of operation in VF-HF hybrid CWs. Results demonstrate that the VF-HF hybrid CWs possess good buffer capacity for treating TN from domestic sewage for extended periods of time.
机译:为了探讨垂直流动(VF)的长期氮处理效率 - 水肠流(HF)杂种构造的湿地(CWS),不同季节下的氮气去除效率,N负载和三个操作阶段(代表年龄湿地)在12年期间进行了评估。在运营期间流出物中的平均氮气(TN)去除效率按以下顺序:夏季(75.2%)>弹簧(73.4%)千分之一的零件(72.6%)>冬季( 66.4%)。夏季,秋季和春季的清除效率通常高于冬季的效率。在不同的操作阶段(年),流出物中的平均TN去除率按以下顺序:中期阶段(73.4%; 2006-2009年)>最后阶段(72.0%; 2010-2013年)>开始阶段( 70.1%; 2002-2005年)。在VF-HF CWS中,12年期间的平均TN除去量(Mg N M(-2)天(-1))是夏季(5.5)千分之一份千分之一秋季(5.1)>春季(4.3)千分之一的零件零件百万冬季(4.2)为vf床,按夏季(3.5)零件零件零件零件(3.5)零件每千秋季(3.3)>冬季(2.7)为HF床,表明夏季每单位面积(M(2))的TN拆除量略大于其他季节。 VF床中的TN除去量略大于HF床中的TN。使用三维仿真图,最大TN去除率在夏季进入2.7克(-2)天(-1)下降,而最小TN去除率是在1.4克( - 2)冬季(-1)冬季。因此,在VF-HF杂交CWS的12年的操作中,TN去除效率非常稳定。结果表明,VF-HF杂交CWS具有良好的缓冲能力,用于在延长的时间内从家庭污水处理TN。

著录项

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号