A gap flow cell (gap-FC) as a capillary-end electrochemical (EC) detector, incorporating exchangeable screen-printed electrodes, that facilitates adjustment of the gap distance between the capillary outlet and working electrode down to 30 um was investigated. The analytical performance of the gap-FC was assessed in terms of detector response (current), the efficiency of EC conversion of ferrocyanide, and effective cell volume, as a function of flow rate and gap distance, within a range of 0.1-200 mu L min(-1) and 30-100 mu m, respectively. As a result, an efficiency of EC conversion within the range of similar to 1.5-11% (similar to 3-16 times higher than wall-jet FC), at an effective cell volume of similar to 30-75 nL, was achieved. The gap-FC was applied as a liquid chromatography EC detector, coupled with standard and capillary format liquid chromatographs, where the analytical performance of gap-FC was compared with that of a UV detector. With the standard LC, the sensitivity for ascorbic acid, 2,3-dihydroxybenzoic acid and pyrocatechol, was greater than with the UV detector, with limits of detection (LODs) one order of magnitude lower for the gap-FC (0.10 mu M, 0.09 mu M, 0.19 mu M, respectively, RSD 1.35-3.8%, n = 9, linearity r(2) similar to 0.99 for concentration range 1-100 mu M). LODs of test electroactive solutes using the gap-FC were similar to 2 times lower than LODs reported in existing literature using standard EC detectors, including wall-jet and thin-layer FCs. (C) 2019 Published by Elsevier Ltd.
机译:间隙流动池(GAP-FC)作为毛细管 - 端电化学(EC)检测器,包括可交换的丝网印刷电极,其有助于调节毛细管出口和工作电极之间的间隙距离下降至30μm。在检测器响应(电流),均氰化物的EC转化效率和有效细胞体积的效率评估GAP-Fc的分析性能,以及流速和间隙距离的函数,在0.1-200μm的范围内L min(-1)和30-100 mu m。结果,实现了EC转化的效率,在类似于与30-75ng的有效细胞体积的类似细胞体积的相似范围内的EC转化率在类似于1.5-11%(比壁射Fc的3-16倍)。将GAP-Fc用作液相色谱EC检测器,与标准和毛细管格式的液相色谱仪相结合,其中GAP-Fc的分析性能与UV检测器的分析性能进行了比较。利用标准LC,抗坏血酸,2,3-二羟基苯甲酸和PyrocateChol的敏感性大于UV检测器,具有检测限(LOD)对于GAP-Fc(0.10μm, 0.09μm,0.19μm,分别为1.35-3.8%,n = 9,线性r(2),其浓度范围为1-100μm)。使用GAP-Fc的测试电活性溶质的宿床类似于使用标准EC探测器在现有文献中报告的LOD的2倍,包括壁射流和薄层FC。 (c)2019年由elestvier有限公司发布

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号