首页> 外文期刊>Investigative ophthalmology & visual science >Application of a novel interferometric method to investigate the relation between lipid layer thickness and tear film thinning.
【24h】

Application of a novel interferometric method to investigate the relation between lipid layer thickness and tear film thinning.

机译:一种新型干涉法的应用研究脂层厚度与撕裂薄膜稀薄关系的关系。

获取原文
获取原文并翻译 | 示例
           

摘要

PURPOSE: The lipid layer of the tear film forms a barrier to evaporation. Evaporation is a major cause of tear thinning between blinks and tear breakup. The purpose of this study was to investigate the relation between tear film thinning and lipid layer thickness before and after instillation of an emulsion eye drop. METHODS: Fifty non-contact lens wearers were studied. Spectral interferometry was used to measure the thinning rate of the precorneal tear film for up to 19 seconds after a blink. Simultaneously, lipid layer thickness was measured based on an absolute reflectance spectrum. After a 2-minute recovery, the measurement was repeated. A drop of the lipid emulsion was then instilled; 15 minutes later, two interferometry measurements were performed similarly. RESULTS: A histogram of thinning rates was fitted by a bimodal distribution with narrow and broad peaks corresponding to slow and rapid thinning, respectively. The correlation between repeated thinning rate measurements was modest, but repeatability was considerably more significant when analyzed in terms of the slow/rapid dichotomy. Similarly, the correlation between thinning rate and lipid thickness was modest but was more evident when analyzed in terms of the slow/rapid dichotomy. Instillation of an emulsion eye drop significantly increased the thickness of the lipid layer but did not significantly alter the thinning rate. CONCLUSIONS: The proposed slow/rapid dichotomy of thinning rates presumably relates to a good/poor barrier to evaporation of the lipid layer. The imperfect correlation between thinning rate and lipid thickness indicates that other factors, such as the composition and structure of the lipid layer, are important (e.g., sufficient polar lipids may be needed to form good interface between nonpolar lipids and the aqueous layer).
机译:目的:撕裂膜的脂质层形成蒸发屏障。蒸发是眨眼和撕裂分手之间撕裂的主要原因。本研究的目的是探讨乳液滴眼液滴注前后撕裂膜变薄和脂质层厚度之间的关系。方法:研究了五十个非隐形眼镜佩戴者。光谱干涉测量用于测量闪烁后预荷撕裂膜的稀释速率最多19秒。同时,基于绝对反射谱测量脂质层厚度。经过2分钟的恢复后,重复测量。然后滴注一滴脂乳液; 15分钟后,类似地进行两次干涉测量。结果:双模分布分别狭窄,宽峰的双峰分布分别缩小,分别对应于缓慢和快速变薄,缩放速率的直方图。重复薄速率测量之间的相关性是适度的,但在慢速/快速二分法方面分析时,可重复性会更显着。类似地,稀疏率和脂质厚度之间的相关性是适度的,但在慢/快速的二分法方面分析时更明显。乳液滴眼液的滴注显着增加了脂质层的厚度,但没有显着改变稀释率。结论:稀释率的提议缓慢/快速二分术可能与脂质层蒸发的良好/差的屏障有关。稀释率和脂质厚度之间的不完全相关性表明其他因素,例如脂质层的组成和结构,是重要的(例如,可能需要足够的极性脂质来在非极性脂质和水层之间形成良好的界面)。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号