Development and Testing of a Magnetic Resonance (MR) Conditional Afterloader for Source Tracking in Magnetic Resonance Imaging-Guided High-Dose-Rate (HDR) Brachytherapy

机译:用于磁共振成像引导的高剂量率(HDR)近距离放射治疗的磁共振(MR)条件后加载器的磁共振(MR)条件后加载器的开发和测试

获取原文
获取原文并翻译 | 示例
           

摘要

PurposeFor the purpose of magnetic resonance imaging (MRI)-guided high-dose-rate (HDR) brachytherapy, a prototype magnetic resonance (MR) conditional afterloader was developed. This study demonstrates the development and testing of the prototype, while operating simultaneously with MRI. In combination with an MR-based method for HDR source localization, this development enables treatment verification of HDR brachytherapy. Additionally, this allows a direct reconstruction of the source dwell positions after catheter insertion (when using a dummy source) and introduction of a clinical workflow where the patient remains in the same position during dwell position reconstruction, treatment planning and irradiation. Methods and materialsA prototype MR conditional afterloader was developed by providing radiofrequency (RF) shielding and a plastic source cable containing a dummy source. Simultaneous functioning of the afterloader and MRI acquisition was tested in an experimental setting where the afterloader was placed next to the scanner and programmed to send the source to predefined positions within a phantom, while acquiring MR images. The HDR source positions were determined using MR artifact simulation and matching of the MR images to the simulated artifact. Additionally, the impact of the presence and use of the afterloader on the MRI performance was investigated by assessment of RF interference, signal-to-noise ratio (SNR), and B0field homogeneity. ResultsThe experiments demonstrated that the prototype MR conditional afterloader and the MRI scanner fully functioned while operating simultaneously, without influencing the other system. The step sizes between the source positions obtained from the MR images corresponded with the afterloader settings. Besides, the MRI performance tests demonstrated no deterioration due to the presence or functioning of the afterloader next to the scanner. ConclusionsThis research has demonstrated the feasibility of simultaneous MR acquisition and employment of an MR conditional afterloader. This development enables real-time HDR source localization for treatment verification of MRI-guided HDR brachytherapy using an MR conditional afterloader.
机译:目的是为了磁共振成像(MRI) - 导向高剂量率(HDR)近距离放射治疗的目的,开发了原型磁共振(MR)条件后加载物。本研究展示了原型的开发和测试,同时与MRI同时操作。结合基于MR的HDR源定位方法,该发展使HDR近距离放射治疗的治疗核实。另外,这允许在导管插入后(使用伪源时)直接重建源停留位置,并引入患者在停留位置重建期间保持在相同位置,治疗计划和辐照。方法和材料通过提供射频(RF)屏蔽和包含虚设源的塑料源电缆来开发方法和材料原型MR条件后载荷。在扫描仪旁边放置的实验设置中测试了后加载器和MRI采集的同时运行,并在扫描仪旁边被编程为将源送到幻像内的预定位置,同时获取MR图像。使用MR神器模拟和MR图像与模拟伪像的匹配确定HDR源位置。另外,通过评估RF干扰,信噪比(SNR)和B0FIELD均匀性,研究了在MRI性能上的存在和使用的影响。结果实验证明了原型MR条件的后载器和MRI扫描仪在同时运行时完全运行,而不会影响其他系统。从MR图像获得的源位置之间的步骤尺寸对应于后加载器设置。此外,由于扫描仪旁边的后载器的存在或运作,MRI性能测试不会劣化。结论STRHIS研究表明,同时先生采集和就业的可行性。该开发使实时HDR源定位能够使用MR条件后加载器治疗MRI引导的HDR近距离放射治疗的治疗验证。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号