...
首页> 外文期刊>International Journal of Pharmaceutics >Evaluation of sorption capacity of antibiotics and antibacterial properties of a cyclodextrin-polymer functionalized hydroxyapatite-coated titanium hip prosthesis
【24h】

Evaluation of sorption capacity of antibiotics and antibacterial properties of a cyclodextrin-polymer functionalized hydroxyapatite-coated titanium hip prosthesis

机译:抗生素吸附能力评价及环糊精聚合物官能化羟基磷灰石涂层钛髋关节假体的抗菌性能

获取原文
获取原文并翻译 | 示例

摘要

Infection still present as one of common complications after total hip replacement (similar to 2.5%), which may cause serious outcomes. For preventing such risk, loading antibiotics onto implants for increasing local drug concentration at targeted sites could be a solution. This study aims at modifying the surface of hydroxyapatite (HA) coated titanium hip implant material (Ti-HA) with polymer of cyclodextrin (polyCD) for loading antibiotics, to achieve a sustained local drug delivery. Two widely applied antibiotics (tobramycin and rifampicin) in orthopedic surgery were loaded alone or in combination. The drug adsorption isotherm, drug release kinetics and drug's efficacy were thoroughly investigated. The results proved that polyCD coating significantly improved the affinity of both drugs to Ti-HA surface, while the mechanism of drug-polyCD interaction varies from the nature of drug, courtesy of the structural complex of polyCD. The advantage of dual-drug loading was highlighted by its strong efficacy against both Staphylococcus aureus and Enterobacter cloacae, which overcomes the limitation of mono-drug loading for an effective treatment against both bacterial strains. The prolonged antibacterial activity of antibiotic loaded Ti-HA-polyCD samples confirmed that polyCD could be a promising drug-delivery system, for sustained antibiotics release or other potential applications e.g., antimitotic agent release. (C) 2014 Elsevier B.V. All rights reserved.
机译:感染仍然作为总髋关节替代(类似于2.5%)后的常见并发症之一,这可能导致严重结果。为了防止这种风险,将抗生素加载到用于增加靶向位点的局部药物浓度的植入物中可能是溶液。本研究旨在通过环糊精(PolyCd)的聚合物来改变羟基磷灰石(HA)涂覆的钛髋瓣植入物质(Ti-HA)的表面,用于加载抗生素,以达到持续的局部药物递送。两种广泛应用的抗生素(染发霉素和利福平)单独或组合加载整形外科手术。彻底研究了药物吸附等温线,药物释放动力学和药物的功效。结果证明,Polycd涂料显着改善了药物对Ti-HA表面的亲和力,而药物 - Polycd相互作用的机制因药物的性质而异,由PolyCd的结构络合物提供。通过其对金黄色葡萄球菌和肠杆菌的强疗效来突出了双药物负荷的优点,这克服了单药载荷的限制,以有效处理对细菌菌株的有效处理。抗生素负载的Ti-ha-polycd样品的延长抗菌活性证实,Polycd可以是有前途的药物输送系统,用于持续抗生素释放或其他潜在应用,例如抗杀菌剂释放。 (c)2014 Elsevier B.V.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号