In this study, an electrolyte-dielectric-metal (EDM) device incorporating a high-k (high dielectric constant) Al2O3 sensing template from porous anodic aluminum-oxide (AAO) was fabricated through a two-step anodizing process for pH detection. In order to change the morphologies of the AAO template, the anodization solution was varied by controlling the electrolyte. Getting the AAO template having a structure through this experiment was EDM measure the pH sensitivity changes according to the surface area. AAO templates were characterized by X-ray diffraction and field-emission scanning electron microscopy (FE-SEM). The anodic aluminum oxide template for pH sensors went through the following steps: 1st anodizing step at 90 V for 6 h (0.3 M, H3PO4); 2nd anodizing step at 90 V for 1 min (H3PO4 0.3 M); and pore widening for 30 min. The device displayed a good sensitivity of 54.2 mV/pH.
机译:在这项研究中,通过两步阳极氧化工艺制造了一种电解质-介电金属(EDM)装置,该装置结合了由多孔阳极氧化铝(AAO)制成的高k(高介电常数)Al2O3感应模板。为了改变AAO模板的形态,通过控制电解质来改变阳极氧化溶液。通过该实验获得具有结构的AAO模板是通过EDM测量pH敏感度根据表面积的变化。通过X射线衍射和场发射扫描电子显微镜(FE-SEM)对AAO模板进行了表征。用于pH传感器的阳极氧化铝模板经过以下步骤:第一个在90 V下进行阳极氧化的步骤,时间为6 h(0.3 M,H3PO4);第二个阳极氧化步骤,在90 V下进行1分钟(H3PO4 0.3 M);和毛孔扩大30分钟。该设备显示出54.2 mV / pH的良好灵敏度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号