A novel polymeric micelle, formed by random copolymer poly (stearyl methacrylate-co-methacrylic acid) (P(SMA-co-MAA)) has been used as pseudostationary phase (PSP) in electrokinetic chromatography (EKC) for simultaneous and rapid determination of 11 kinds of water- and fat-soluble vitamins in this work. The running buffer consisting of 1% (w/v) P(SMA-co-MM), 10% (v/v) 1-butanol, 20% (v/v) acetonitrile, and 30 mM Palitzsch buffer solution (pH 9.2) was applied to improve the selectivity and efficiency, as well as to shorten analysis time. 1-Butanol and acetonitrile as the organic solvent modifiers played the most important roles for rapid separation of these vitamins. The effects of organic solvents on microstructure of the polymeric micelle were investigated. The organic solvents swell the polymeric micelle by three folds, lower down the surface charge density and enhance the microenviromental polarity of the polymeric micelle. The 11 kinds of water- and fat-soluble vitamins could be baseline separated within 13 min. The method was applied to determine water- and fat-soluble vitamins in commercial vitamin sample; the recoveries were between 93% and 111% with the relative standard derivations (RSDs) less than 5%. The determination results matched the label claim. (C) 2014 Elsevier B.V. All rights reserved.
机译:由电动共聚色谱法(EKC)中的伪平稳相(PSP)使用由无规共聚物聚甲基丙烯酸十八烷基酯-共-甲基丙烯酸(P(SMA-co-MAA))形成的新型聚合物胶束同时快速测定这项工作中有11种水溶性和脂溶性维生素。运行缓冲液由1%(w / v)P(SMA-co-MM),10%(v / v)1-丁醇,20%(v / v)乙腈和30 mM Palitzsch缓冲溶液(pH 9.2)组成)用于提高选择性和效率,以及缩短分析时间。 1-丁醇和乙腈作为有机溶剂改性剂,对快速分离这些维生素起着最重要的作用。研究了有机溶剂对聚合物胶束微观结构的影响。有机溶剂使聚合物胶束溶胀三倍,降低了表面电荷密度并增强了聚合物胶束的微环境极性。可以在13分钟内对11种水溶性和脂溶性维生素进行基线分离。该方法用于测定商业维生素样品中的水溶性和脂溶性维生素。回收率在93%至111%之间,相对标准偏差(RSD)小于5%。确定结果与标签要求相符。 (C)2014 Elsevier B.V.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号