首页> 外文期刊>Journal of chromatography, A: Including electrophoresis and other separation methods >High polar organic-inorganic hybrid coating stir bar sorptive extraction combined with high performance liquid chromatography-inductively coupled plasma mass spectrometry for the speciation of seleno-amino acids and seleno-oligopeptides in biological samples
【24h】

High polar organic-inorganic hybrid coating stir bar sorptive extraction combined with high performance liquid chromatography-inductively coupled plasma mass spectrometry for the speciation of seleno-amino acids and seleno-oligopeptides in biological samples

机译:高极性有机-无机杂化涂层搅拌棒吸附萃取与高效液相色谱-电感耦合等离子体质谱联用对生物样品中的硒氨基酸和硒寡肽形成

获取原文
获取原文并翻译 | 示例
           

摘要

In this work, partially sulfonated polystyrene-titania (PSP-TiO _2) organic-inorganic hybrid stir bar coating was prepared by sol-gel and blending methods, and a new method of PSP-TiO _2 coating stir bar sorptive extraction (SBSE)-high performance liquid chromatography (HPLC)-inductively coupled plasma mass spectrometry (ICP-MS) was established for the analysis of seleno-amino acids (selenocystine (SeCys _2), methylseleno-cysteine (MeSeCys), selenomethionine (SeMet) and selenoethionine (SeEt)) and seleno-oligopeptides (γ-glutamyl-Se-methyl-selenocysteine (γ-GluMeSeCys) and selenodiglutathione (GS-Se-SG)) in biological samples. The prepared high polar PSP-TiO _2 hybrid coating avoided the swelling of PSP and cracking of TiO _2 coating by combining the good film-forming property of PSP with the high mechanical strength of TiO _2. The scanning electron microscope (SEM) showed that no obvious swelling and damage occurred for the PSP-TiO _2 hybrid stir bar coating after 30 extraction/desorption cycles. The preparation reproducibility of PSP-TiO_2 coated stir bar, evaluated with the relative standard deviations (RSDs), was in the range of 6.7-12.6% (n=5) in one batch, and 9.9-17.6% (n=7) among different batches. The limits of detection (LODs) of the developed method for six target selenium species were in the range of 50.2-185.5ngL ~(-1) (as ~(77)Se) and 45.9-158.8ngL ~(-1) (as ~(82)Se) with the RSDs within 4.9-11.7%. The dynamic linear range was found to cover three orders of magnitude with correlation coefficient of 0.9995-0.9999. The developed method was applied for the analysis of Certified Reference Material SELM-1 selenium enriched yeast and the determined values were in good agreement with the certified values. The method has also been applied for the analysis of seleno-amino acids and seleno-oligopeptides in human urine and garlic samples. Different from the conventional organic polymer SBSE coatings (such as polydimethylsiloxane, PDMS), the extraction mechanism of PSP-TiO _2 organic-inorganic hybrid SBSE coating was based on the cation exchange interaction, which made it feasible to directly extract high polar seleno-amino acids and seleno-oligopeptides in biological samples without derivatization. This coating could also be suitable for stir bar sorptive extraction of other cationic compounds from the environmental and biological samples.
机译:本文采用溶胶-凝胶法和共混法制备了部分磺化的聚苯乙烯-二氧化钛(PSP-TiO _2)有机-无机杂化搅拌棒涂料,并提出了一种新的PSP-TiO _2涂层搅拌棒吸附萃取(SBSE)-建立了高效液相色谱(HPLC)-电感耦合等离子体质谱(ICP-MS)用于分析硒氨基酸(硒代胱氨酸(SeCys _2),甲基硒代半胱氨酸(MeSeCys),硒代蛋氨酸(SeMet)和硒代乙硫氨酸(SeEt) ))和生物样品中的硒低聚肽(γ-谷氨酰-Se-甲基-硒代半胱氨酸(γ-GluMeSeCys)和硒二谷胱甘肽(GS-Se-SG))。所制备的高极性PSP-TiO _2杂化涂层通过将PSP的良好成膜性能与TiO _2的高机械强度相结合,避免了PSP的溶胀和TiO _2涂层的开裂。扫描电子显微镜(SEM)显示,经过30次萃取/解吸循环后,PSP-TiO _2混合搅拌棒涂层没有出现明显的溶胀和损坏。用相对标准偏差(RSD)评估的PSP-TiO_2涂层搅拌棒的制备再现性在一批中的范围为6.7-12.6%(n = 5),在其中为9.9-17.6%(n = 7)不同批次。所开发方法对6种目标硒物种的检出限(LOD)在50.2-185.5ngL〜(-1)(以〜(77)Se)和45.9-158.8ngL〜(-1)(以〜(82)Se),相对标准偏差在4.9-11.7%之间。动态线性范围被发现覆盖三个数量级,相关系数为0.9995-0.9999。所开发的方法用于分析认证参考物质SELM-1富硒酵母,测定值与认证值高度吻合。该方法也已用于分析人类尿液和大蒜样品中的硒氨基酸和硒寡肽。与传统的有机聚合物SBSE涂料(如聚二甲基硅氧烷,PDMS)不同,PSP-TiO _2有机-无机杂化SBSE涂料的萃取机理是基于阳离子交换作用,使得直接萃取高极性硒基氨基化合物成为可能不衍生化的生物样品中的氨基酸和硒代寡肽。这种涂层也可能适用于搅拌棒从环境和生物样品中吸附其他阳离子化合物。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号