首页> 外文期刊>Journal of chromatography, A: Including electrophoresis and other separation methods >Evaluation of a generic multi-analyte method for detection of 100 representative compounds correlated to emergency events in 19 food types by ultrahigh-pressure liquid chromatography-tandem mass spectrometry
【24h】

Evaluation of a generic multi-analyte method for detection of 100 representative compounds correlated to emergency events in 19 food types by ultrahigh-pressure liquid chromatography-tandem mass spectrometry

机译:超高压液相色谱-串联质谱法检测19种食品中与紧急事件相关的100多种代表性化合物的通用多分析物方法的评估

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

A generic extraction procedure combined with triple quadrupole mass spectrometric detection was evaluated for multi-residue analysis in 19 different foods. Measurable peaks could be obtained at relevant concentrations for 108 out of a total of 127 targeted compounds representing a wide range of physicochemical properties and compound classes related to emergency situations. Recoveries were determined for all 19 foods spiked with the 108 compounds. Seventy-five percent of the compounds had extraction recoveries of 70% or higher, with no compound below 46%. Suppression or enhancement effects on the MS response of the compounds dissolved in the extracts were low, as more than 80% of them had matrix effects between -35% and +20% and no compound was below -44% compared to matrix-free standard. In a validation, all compounds could be quantified at 200 μg/kg and 400 μg/kg food sample and 81% of the compounds at 40 μg/kg. It is concluded that the method is useful for the detection of various types of organic chemical toxicants at levels generally well below concentration thresholds for severe acute intoxication.
机译:评价了一种通用提取程序与三重四极杆质谱检测相结合的方法,以对19种不同食品中的多残留物进行分析。在127种目标化合物中,有108种在相关浓度下可获得可测量的峰,这些化合物代表了广泛的理化性质和与紧急情况相关的化合物类别。确定加标有108种化合物的所有19种食物的回收率。百分之七十五的化合物具有70%或更高的提取回收率,没有化合物低于46%。相对于不含基质的标准品,提取物中溶解的化合物对MS反应的抑制或增强作用较低,因为其中80%以上的化合物具有-35%至+ 20%的基质效应,没有化合物低于-44% 。在验证中,所有化合物的定量含量分别为200μg/ kg和400μg/ kg食品样品,其中81%的化合物定量为40μg/ kg。结论是该方法可用于检测各种类型的有机化学毒物,其水平通常远低于严重急性中毒的浓度阈值。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号