首页> 外文期刊>Journal of chromatography, A: Including electrophoresis and other separation methods >Simple and commercial readily-available approach for the direct use of ionic liquid-based single-drop microextraction prior to gas chromatography Determination of chlorobenzenes in real water samples as model analytical application
【24h】

Simple and commercial readily-available approach for the direct use of ionic liquid-based single-drop microextraction prior to gas chromatography Determination of chlorobenzenes in real water samples as model analytical application

机译:在气相色谱法之前直接使用基于离子液体的单滴微萃取的简单且商业易得的方法,用于测定实际水样中的氯苯作为模型分析应用

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

A simple and commercial readily-available approach that enables the direct use of ionic liquid (IL)-based single-drop microextraction (SDME) prior to gas chromatography (GC) is presented. The approach is based on thermal desorption (TD) of the analytes from the IL droplet to the GC system, by using a robust and commercially-available thermodesorption system. For this purpose, a two-glass-tube concentrically disposed system was designed. The inner tube is a laboratory-cut Pyrex tube (20 mm length) that houses the ionic liquid droplet from the SDME process, and the outer tube is a commercially-available TD glass tube (187 mm length) commonly employed for stir-bar sorptive extractions (SBSE). In this way, the proposed device prevents IL from entering the GC system, as this could dirty the inlet or even block the column. The determination of 10 chlorobenzenes in water samples by GC coupled with mass spectrometric(MS) detection has been chosen as model analytical application, showing the feasibility of the proposed approach. The SDME process consists of a 5 p,L droplet of 1-hexyl-3-methylimidazolium hexafluorophosphate ([C6MIM][PF6]) suspended in the headspace (HS) of a 10mL stirred sample. After extracting for 37 min at room temperature, the IL droplet is directly placed into the small inner tube, which is placed into the TD tube. The whole device is placed inside the TD unit, where desorption of the analytes is performed at 240 degrees C for 5 min with a helium flow rate of 100 mL min(-1). The analytical figures of merit of the proposed IL-(HS)-SDME-TD-GC-MS approach are very suitable for the determination of chlorobenzenes at ultratrace levels, with relative standard deviation values ranging between 2% and 17%, and limits of detection ranging between 1 and 4 ng L-1, showing the potential offered by the IL-based SDME process with GC. (C) 2008 Elsevier B.V. All rights reserved.
机译:提出了一种简单且易于商业使用的方法,该方法能够在气相色谱(GC)之前直接使用基于离子液体(IL)的单滴微萃取(SDME)。该方法基于分析物从IL液滴到GC系统的热脱附(TD),方法是使用功能强大且可商购的热脱附系统。为此,设计了一个两管同心放置的系统。内管是实验室切割的派热克斯玻璃管(长20毫米),用于容纳SDME工艺中的离子液滴,外管是市售的TD玻璃管(长187毫米),通常用于搅拌棒吸附提取(SBSE)。这样,建议的设备可防止IL进入GC系统,因为这可能弄脏进样口甚至阻塞色谱柱。选择了气相色谱-质谱联用法测定水样中10种氯苯作为模型分析应用,证明了该方法的可行性。 SDME过程由悬浮在10mL搅拌样品的顶空(HS)中的5 p,L六氟磷酸1-己基-3-甲基咪唑鎓([C6MIM] [PF6])液滴组成。在室温下提取37分钟后,将IL液滴直接放入小内管中,将其放入TD管中。整个设备被放置在TD单元内,在这里,分析物的解吸在240摄氏度,氦气流速为100 mL min(-1)下进行5分钟。拟议的IL-(HS)-SDME-TD-GC-MS方法的品质因数非常适合于超痕量水平的氯苯测定,相对标准偏差范围为2%至17%,极限范围为检测范围介于1到4 ng L-1之间,显示了基于IL的SDME工艺和GC的潜力。 (C)2008 Elsevier B.V.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号