Sedimentation velocity runs were performed on organic and inorganic particles with analytical ultracentrifugation and the diameter and diameter distribution analysis was carried out with Sedfit and VelXLAI data analysis programs. The particles were measured either as pure components or as mixtures of different organic or inorganic particles using different weight ratios of these components. Polymer particles with peak diameters of ≈15 and 32-35. nm and inorganic particles with peak diameters of ≈5 and ≈32. nm were used and the particles also differed in the extent of polydispersity. The mixtures of particles in the weight ratios of 50:50, 90:10 and 95:5 of smaller to larger particles or vice versa were studied. The aim was to compare the performance of the analysis programs to characterize the various polymer and inorganic particle samples of varying complexity. The analysis programs were compared with each other not only for peak particle diameters and their size distributions, but also for the cumulative fractions of components of the particle mixtures.
机译:通过分析超速离心对有机和无机颗粒进行沉降速度试验,并使用Sedfit和VelXLAI数据分析程序进行直径和直径分布分析。使用这些组分的不同重量比,将这些颗粒测量为纯组分或不同有机或无机颗粒的混合物。峰值直径约为15和32-35的聚合物颗粒。纳米和无机粒子的峰值直径分别为≈5和≈32。使用了100nm,并且颗粒的多分散程度也不同。研究了小颗粒与大颗粒的重量比为50:50、90:10和95:5的颗粒混合物,反之亦然。目的是比较分析程序的性能,以表征复杂程度各异的各种聚合物和无机颗粒样品。不仅对峰粒径及其大小分布进行了分析程序的比较,而且还对了颗粒混合物各组分的累积分数进行了比较。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号