Pulp and paper mill effluents represent a challenge when treatment technologies are considered, not only to reduce organic matter, but also to reduce the toxicological effects. Although anaerobic treatment has shown promising results, as well as advantages when compared with an aerobic system, this process alone is not sufficient to reduce recalcitrant compounds. Thus, an advanced oxidation process was applied. This experiment was performed to determine the effect of ozone and ozone/UV treating a horizontal anaerobic immobilized biomass reactor effluent from a kraft cellulose pulp mill for 306 days with an organic volumetric load of 2.33 kgCOD/m(3)/day. The removal of organic compounds was measured by the following parameters: adsorbable organically bound halogens (AOX), total phenols, chemical oxygen demand (COD), dissolved organic carbon and absorbance values in the UV-visible spectral region. Moreover, ecotoxicity and genotoxicity tests were conducted before and after treatment with ozone and ozone/UV. At an applied ozone dosage of 0.76 mgO(3)/mgCOD and an applied UV dosage of 3.427 Wh/m(3), the organochlorine compounds measured as AOX reached removal efficiencies of 40%. Although the combination of ozone/UV showed better results in colour (79%) and total phenols (32%) compared with only ozone, the chronic toxicity and the genotoxicity that had already been removed in the anaerobic process were slightly increased.
机译:当考虑使用处理技术时,纸浆和造纸厂的废水不仅是减少有机物,而且要减少毒理学影响的挑战。尽管厌氧处理已显示出令人鼓舞的结果以及与有氧系统相比的优势,但仅此过程不足以减少顽固性化合物。因此,采用了先进的氧化工艺。进行该实验以确定臭氧和臭氧/紫外线处理牛皮纸制浆厂的水平厌氧固定化生物质反应器废水306天的效果,有机容量为2.33 kgCOD / m(3)/天。通过以下参数测量有机化合物的去除:可吸附的有机结合卤素(AOX),总酚,化学需氧量(COD),溶解的有机碳和紫外可见光谱区域中的吸光度值。此外,在用臭氧和臭氧/紫外线处理之前和之后进行了生态毒性和遗传毒性测试。在施加的臭氧剂量为0.76 mgO(3)/ mgCOD和施加的UV剂量为3.427 Wh / m(3)时,测得的有机氯化合物的AOX去除率达到40%。尽管与仅臭氧相比,臭氧/紫外线的组合在颜色(79%)和总酚(32%)上显示出更好的结果,但已在厌氧过程中去除的慢性毒性和遗传毒性略有增加。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号