Monitoring the performance of a storm water separating manifold with distributed temperature sensing

机译:使用分布式温度感应器监控雨水分离歧管的性能

获取原文
获取原文并翻译 | 示例
           

摘要

Storm water separating manifolds in house connections have been introduced as a cost effective solution to disconnect impervious areas from combined sewers. Such manifolds have been applied by the municipality of Breda, the Netherlands. In order to investigate the performance of the manifolds, a monitoring technique (distributed temperature sensing or DTS) using fiber optic cables has been applied in the sewer system of Breda. This paper describes the application of DTS as a research tool in sewer systems. DTS proves to be a powerful tool to monitor the performance of (parts of) a sewer system in time and space. The research project showed that DTS is capable of monitoring the performance of house connections and identifying locations of inflow of both sewage and storm runoff. The research results show that the performance of storm water separating manifolds varies over time, thus making them unreliable.
机译:引入房屋连接中的雨水分离歧管是一种经济有效的解决方案,可将不透水区域与下水道分开。这种歧管已被荷兰布雷达市采用。为了研究歧管的性能,已在布雷达的下水道系统中采用了使用光纤电缆的监控技术(分布式温度感测或DTS)。本文介绍了DTS作为下水道系统研究工具的应用。事实证明,DTS是监视下水道系统(部分)在时间和空间上的性能的强大工具。该研究项目表明,DTS能够监视房屋连接的性能,并识别污水和暴雨径流的流入位置。研究结果表明,雨水分离歧管的性能会随时间而变化,从而使它们不可靠。