...
首页> 外文期刊>Transplantation Proceedings >Comparision of anti-HLA antibodies of kidney transplant candidates with chronic renal failure by two different methods: Flow-PRA and Luminex PRA
【24h】

Comparision of anti-HLA antibodies of kidney transplant candidates with chronic renal failure by two different methods: Flow-PRA and Luminex PRA

机译:用两种不同的方法比较具有慢性肾功能衰竭的肾移植候选者的抗HLA抗体:Flow-PRA和Luminex PRA

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Objective: The aim of the study was to compare anti-HLA antibodies examined as panel-reactive antibody (PRA) in kidney transplant candidates with chronic renal failure (CRF) with the use of 2 methods: Flow-PRA and Luminex-PRA. Methods: CRF patients displaying class I PRA (n = 34) and/or class II PRA (n = 41) were tested by the 2 different methods from April 2012 to September 2012, using antigen-coated beads. Results: Eleven (32.3%) 34 patients tested for class I PRA were female and 23 (67.7%) male; 17 (41.5%) 41 patients tested for class II PRA were female and 24 (58.5%) male. Only 2 patients were preemptive, the others had been subjected to dialysis. The concordance ratio of class I PRA test results between Flow-PRA and Luminex PRA was 67.6%. Whereas 13 samples (38.2%) were positive by Flow-PRA, 22 (64.7%) were positive by Luminex-PRA. Two of the 3 patients not previously immunized were found to be positive only by Luminex PRA; 1 was noted to be positive only by Flow-PRA. Regarding class II PRA screening, the concordance between Flow-PRA and Luminex PRA was 70.7%. Whereas 14 (34.1%) samples were positive for Flow-PRA; 24 (58.5%) were positive for Luminex-PRA. The 2 patients not previously immunized were positive only in Luminex PRA. Conclusions: We speculated that the reason for the low concordance ratios was due to the use of sera that had been previously found to be indeterminate in PRA tests. We also speculated that the low concordance ratios were due to the coating procedure for the beads, which may cause changes in antigenic epitopes and decrease concordance between Flow-PRA and Luminex-PRA.
机译:目的:该研究的目的是使用Flow-PRA和Luminex-PRA这两种方法,比较具有慢性肾功能衰竭(CRF)的肾移植候选者中作为小组反应性抗体(PRA)检测的抗HLA抗体。方法:2012年4月至2012年9月,采用抗原包被的磁珠通过两种不同的方法对显示I类PRA(n = 34)和/或II类PRA(n = 41)的CRF患者进行检测。结果:11例(32.3%)34例接受I级PRA检查的患者为女性,男性23例(67.7%); II类PRA测试的17例(41.5%)41例患者为女性,男性24例(58.5%)。只有2例患者处于抢先状态,其他患者都接受了透析。 Flow-PRA和Luminex PRA的I类PRA测试结果的一致性比率为67.6%。 Flow-PRA阳性的样品为13个(38.2%),Luminex-PRA阳性的样品为22个(64.7%)。仅Luminex PRA发现3名先前未免疫的患者中有2名阳性。仅Flow-PRA指出1为阳性。关于II级PRA筛查,Flow-PRA与Luminex PRA的一致性为70.7%。而14个样本(34.1%)的Flow-PRA阳性; Luminex-PRA阳性24例(58.5%)。之前未免疫的2例患者仅在Luminex PRA中呈阳性。结论:我们推测一致性比率低的原因是由于使用先前在PRA测试中无法确定的血清。我们还推测,较低的一致性比率是由于珠子的涂覆过程引起的,这可能会导致抗原表位的变化并降低Flow-PRA和Luminex-PRA之间的一致性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号