首页> 外文期刊>The Journal of Urology >Assessment of a modified acoustic lens for electromagnetic shock wave lithotripters in a swine model
【24h】

Assessment of a modified acoustic lens for electromagnetic shock wave lithotripters in a swine model

机译:猪模型中用于电磁冲击波碎石机的改进声透镜的评估

获取原文
获取原文并翻译 | 示例
           

摘要

Purpose: The acoustic lens of the Modularis electromagnetic shock wave lithotripter (Siemens, Malvern, Pennsylvania) was modified to produce a pressure waveform and focal zone more closely resembling that of the original HM3 device (Dornier Medtech, Wessling, Germany). We assessed the newly designed acoustic lens in vivo in an animal model. Materials and Methods: Stone fragmentation and tissue injury produced by the original and modified lenses of the Modularis lithotripter were evaluated in a swine model under equivalent acoustic pulse energy (about 45 mJ) at 1 Hz pulse repetition frequency. Stone fragmentation was determined by the weight percent of stone fragments less than 2 mm. To assess tissue injury, shock wave treated kidneys were perfused, dehydrated, cast in paraffin wax and sectioned. Digital images were captured every 120 μm and processed to determine functional renal volume damage. Results: After 500 shocks, the mean ± SD stone fragmentation efficiency produced by the original and modified lenses was 48% ± 12% and 52% ± 17%, respectively (p = 0.60). However, after 2,000 shocks, the modified lens showed significantly improved stone fragmentation compared to the original lens (mean 86% ± 10% vs 72% ± 12%, p = 0.02). Tissue injury caused by the original and modified lenses was minimal at a mean of 0.57% ± 0.44% and 0.25% ± 0.25%, respectively (p = 0.27). Conclusions: With lens modification the Modularis lithotripter demonstrates significantly improved stone fragmentation with minimal tissue injury at a clinically relevant acoustic pulse energy. This new lens design could potentially be retrofitted to existing lithotripters, improving the effectiveness of electromagnetic lithotripters.
机译:目的:对Modularis电磁冲击波碎石机(Siemens,Malvern,Pennsylvania)的声学透镜进行了修改,以产生与原始HM3设备(Dornier Medtech,Wessling,德国)相近的压力波形和聚焦区。我们在动物模型中评估了体内新设计的声透镜。材料和方法:在猪模型中,在等效声脉冲能量(约45 mJ)下,以1 Hz脉冲重复频率评估了Modularis碎石机原始透镜和改良透镜产生的碎石和组织损伤。石头碎裂是由小于2 mm的石头碎块的重量百分比确定的。为了评估组织损伤,将经冲击波处理的肾脏灌注,脱水,用石蜡浇铸并切片。每120μm捕获数字图像并进行处理以确定功能性肾体积损害。结果:经过500次电击后,原始镜片和改良镜片产生的平均±SD碎石效率分别为48%±12%和52%±17%(p = 0.60)。但是,经过2,000次电击后,与原始镜片相比,改良镜片显示出明显的碎石效果(平均86%±10%对72%±12%,p = 0.02)。原始镜片和改良镜片造成的组织损伤最小,分别为0.57%±0.44%和0.25%±0.25%(p = 0.27)。结论:通过对晶状体进行改装,Modularis碎石机在临床相关的声脉冲能量下,可显着改善结石碎裂,将组织损伤降至最低。这种新的透镜设计可以潜在地改造为现有的碎石机,从而提高电磁碎石机的效率。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号