...
首页> 外文期刊>The Journal of Urology >Re: Differentiation of kidney stones using dual-energy CT with and without a tin filter
【24h】

Re: Differentiation of kidney stones using dual-energy CT with and without a tin filter

机译:回复:使用双能CT(有或没有锡过滤器)鉴别肾结石

获取原文
获取原文并翻译 | 示例
           

摘要

Objective: The aim of this in vitro study was to examine the capability of three protocols of dual-energy CT imaging in distinguishing calcium oxalate, calcium phosphate, and uric acid kidney stones. Materials and Methods: A total of 48 calcium oxalate, calcium phosphate, and uric acid human kidney stone samples were placed in individual containers inside a cylindric water phantom and imaged with a dual-energy CT scanner using the following three scanning protocols of different combinations of tube voltage, with and without a tin filter: 80 and 140 kVp without a tin filter, 100 and 140 kVp with a tin filter, and 80 and 140 kVp with a tin filter. The mean attenuation value (in Hounsfield units) of each stone was recorded in both low- and high-energy CT images in each protocol. The dual-energy ratio of the mean attenuation values of each stone was computed for each protocol. Results: For all three protocols, the uric acid stones were significantly different (p < 0.001) from the calciferous stones according to their dual-energy ratio values. For differentiating calcium oxalate and calcium phosphate stones, the difference between their dual-energy ratio values was statistically significant, with different degrees of significance (range, p < 0.001 to p = 0.03) for all three protocols. On the basis of the values of the area under receiver operating characteristic curve (AUC) of calcified stone differentiation, the three protocols were ranked in the following order: the 80- and 140-kVp tin filter protocol (AUC, 0.996), the 100- and 140-kVp tin filter protocol (AUC, 0.918), and the 80- and 140-kVp protocol (AUC, 0.871). Conclusion: The tin filter added to the high-energy tube and the use of a wider dual-energy difference are important for improving the stone differentiation capability of dual-energy CT imaging.
机译:目的:这项体外研究的目的是检验双重能量CT成像的三种方案在区分草酸钙,磷酸钙和尿酸肾结石方面的能力。材料和方法:将总共48份草酸钙,磷酸钙和尿酸人肾结石样品放入圆柱水体模内的各个容器中,并使用以下三种不同扫描方式组合的双能CT扫描仪进行成像带和不带锡过滤器的灯管电压:不带锡过滤器的80和140 kVp,带锡过滤器的100和140 kVp,以及带锡过滤器的80和140 kVp。在每种方案的低能和高能CT图像中均记录了每块宝石的平均衰减值(以Hounsfield单位)。对于每种方案,计算了每块宝石的平均衰减值的双能比。结果:对于所有三个方案,根据双能比值,尿酸结石与钙化结石显着不同(p <0.001)。对于区分草酸钙和磷酸钙结石,它们的双重能量比值之间的差异在统计学上是显着的,对于所有三种方案,其显着程度都不同(范围,p <0.001至p = 0.03)。根据钙化结石的接受者工作特征曲线(AUC)下面积的值,按以下顺序对这三个协议进行了排名:80 kVp和140 kVp锡过滤协议(AUC,0.996),100 kV -和140-kVp锡过滤器协议(AUC,0.918)以及80-和140-kVp锡过滤器协议(AUC,0.871)。结论:在高能管中添加锡过滤器并使用更大的双能差对提高双能CT成像的结石分辨能力具有重要意义。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号