Malodorous hydrogen sulfide (H2S) gas often exists in the sewer system and associates with the problems of releasing the dangerous odor to the atmosphere and causing sewer pipe to be corroded. A simple method is in demand for real-time measuring H2S level in the sewer gas. In this paper, an innovated method based on dopant-assisted negative photoionization ion mobility spectrometry (DANP-IMS) with on-line semiconductor cooling inlet was put forward and successfully applied for the real-time measurement of H2S in sewer gas. The influence of moisture was effectively reduced via an on-line cooling method and a non-equilibrium dilution with drift gas. The limits of quantitation for the H2S in >= 60% relative humidity air could be obtained at <= 79.0 ng L-1 with linear ranges of 129-2064 ng L-1. The H2S concentration in a sewer manhole was successfully determined while its product ions were identified by an ion-mobility time-of-fight mass spectrometry. Finally, the correlation between sewer H2S concentration and the daily routines and habits of residents was investigated through hourly or real-time monitoring the variation of sewer H2S in manholes, indicating the power of this DANP-IMS method in assessing the H2S concentration in sewer system. (C) 2016 Elsevier B.V. All rights reserved.
机译:下水道系统中经常存在恶臭的硫化氢(H2S)气体,并伴有向大气释放有害气味并导致下水道管道腐蚀的问题。需要一种简单的方法来实时测量下水道中的H2S水平。提出了一种基于掺杂辅助负离子电离离子迁移谱(DANP-IMS)的在线半导体冷却入口的创新方法,并将其成功应用于污水中H2S的实时测量。通过在线冷却方法和用漂移气进行的非平衡稀释有效地减少了水分的影响。相对湿度> = 60%的空气中H2S的定量限可以在<= 79.0 ng L-1时获得,线性范围为129-2064 ng L-1。成功地确定了下水道井口中的H2S浓度,同时通过离子迁移时间质谱法确定了其产物离子。最后,通过每小时或实时监测下水道井中下水道H2S的变化,研究了下水道H2S浓度与居民日常习惯之间的相关性,表明该DANP-IMS方法在评估下水道系统中H2S浓度方面的作用。 (C)2016 Elsevier B.V.保留所有权利。

著录项

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号