首页> 外文期刊>Talanta: The International Journal of Pure and Applied Analytical Chemistry >Application of the extraction induced by emulsion breaking for the determination of Cu, Fe and Mn in used lubricating oils by flame atomic absorption spectrometry
【24h】

Application of the extraction induced by emulsion breaking for the determination of Cu, Fe and Mn in used lubricating oils by flame atomic absorption spectrometry

机译:破乳诱导萃取在火焰原子吸收光谱法测定废润滑油中铜,铁,锰中的应用

获取原文
获取原文并翻译 | 示例
           

摘要

A novel approach is proposed for the sample preparation of used lubricating oils to determine Cu, Fe and Mn by FAAS. The method is based on the extraction induced by emulsion breaking, in which the elements of interest are transferred to an aqueous phase before the measurement by FAAS. In the method, each sample of used lubricating oil was diluted with toluene (20% v/v) and the resulting solution was emulsified with a Triton X-114 solution containing HNO3. Further, the water-in-oil emulsion was broken by centrifugation for 30 min at 3500 rpm, originating a system with two well-separated phases: (i) the upper phase, containing the used lubricating oil diluted in toluene and (ii) the lower aqueous phase, containing the analytes that were extracted from oil. The lower phase was collected, diluted with water and the analytes were determined by FAAS. The optimization of the methodology was performed by studying the influence of different parameters that could affect the extraction efficiency such as the nature and concentration of the solvent used for sample dilution, the concentrations of HNO3 and Triton X-114 in the solution employed for emulsification and the operational conditions for extraction (extraction, centrifugation and sampling times). The limits of quantification for Cu, Fe and Mn were 2.9, 77 and 8.2 ng g-1, respectively. The accuracy of the method was evaluated by comparison with the reference method based on the total digestion of the samples in a closed-vessel microwave oven. There were no statistical differences between the results obtained with the proposed method and the reference one, except for Fe in the cases where its concentration was higher than 80 mg g-1.
机译:提出了一种新方法,用于通过FAAS测定废润滑油的样品制备,以测定Cu,Fe和Mn。该方法基于破乳引起的萃取,其中在通过FAAS测量之前,将感兴趣的元素转移到水相中。在该方法中,将用过的润滑油的每个样品用甲苯(20%v / v)稀释,并将所得溶液用含有HNO 3的Triton X-114溶液乳化。此外,油包水乳液通过在3500 rpm下离心30分钟而破碎,形成一个具有两个良好分离相的系统:(i)上层,其中包含用甲苯稀释的用过的润滑油,(ii)较低的水相,其中包含从石油中提取的分析物。收集下层相,用水稀释,并通过FAAS测定分析物。方法的优化是通过研究可能影响萃取效率的不同参数的影响来进行的,这些参数可能影响萃取效率,例如用于样品稀释的溶剂的性质和浓度,用于乳化的溶液中的HNO3和Triton X-114的浓度以及提取的操作条件(提取,离心和采样时间)。 Cu,Fe和Mn的定量限分别为2.9、77和8.2 ng g-1。通过与参考方法的比较,基于封闭容器微波炉中样品的总消化率,评估了该方法的准确性。除了Fe的浓度高于80 mg g-1的情况外,用建议的方法获得的结果与参考方法之间没有统计学差异。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号