In this study, a nano-structured copolymer of luminol/aniline (PLA) was deposited onto nano-Ti0_2-functionalised indium tin oxide (ITO)-coated glass by electrochemical polymerisation using cyclic voltammetry (CV). The resulting reagentless electrochemiluminescent (ECL) electrode (ECLode) can be used for flow injection analysis (FIA). The properties of the ECLode were characterised by CV, electrochemical impedance spectroscopy (EIS) and scanning electron microscopy (SEM). The ECLode has high background ECL emission as well as excellent stability and reproducibility, and yielding sensitive response towards target analytes. The ECL emissions of the ECLode were 50 times higher than PLA/ITO, and 500 times higher than polyluminol (PL)/ITO. The ECLode showed sensitive responses to reactive oxygen species (ROSs), permitting its application for determination of antioxidants by quenching. Under optimised conditions, an absolute detection limit of 69.9 pg was obtained for resveratrol, comparable to the highest levels of sensitivity achieved by other methods. Thus, the gross antioxidant content of red wine was determined, with satisfactory recoveries between 87.6% and 108.3%. These results suggest a bright future for the use of the ECLode for single-channel FIA due to its high sensitivity, accuracy and reproducibility.
机译:在这项研究中,通过使用循环伏安法(CV)进行电化学聚合,将鲁米诺/苯胺(PLA)的纳米结构共聚物沉积到纳米TiO_2-官能化的氧化铟锡(ITO)涂层玻璃上。所得的无试剂电化学发光(ECL)电极(ECLode)可用于流动注射分析(FIA)。通过CV,电化学阻抗谱(EIS)和扫描电子显微镜(SEM)对ECLode的特性进行了表征。 ECLode具有很高的背景ECL发射以及出色的稳定性和可重复性,并且对目标分析物产生灵敏的响应。 ECLode的ECL排放量是PLA / ITO的50倍,是聚luminol(PL)/ ITO的500倍。 ECLode对活性氧(ROSs)表现出敏感的反应,使其可用于通过淬灭测定抗氧化剂。在优化的条件下,白藜芦醇的绝对检测极限为69.9 pg,与其他方法获得的最高灵敏度相当。因此,测定了红酒中的总抗氧化剂含量,回收率令人满意,介于87.6%和108.3%之间。这些结果表明,由于ECLode具有高灵敏度,准确性和可重复性,因此有望将其用于单通道FIA。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号