首页> 外文期刊>Cornea >New approach for correction of error associated with keratometric estimation of corneal power in keratoconus
【24h】

New approach for correction of error associated with keratometric estimation of corneal power in keratoconus

机译:校正与圆锥角膜角膜屈光力角膜测量法有关的误差的新方法

获取原文
获取原文并翻译 | 示例
           

摘要

Purpose: The aim of this study was to obtain the exact value of the keratometric index (nkexact) and to clinically validate a variable keratometric index (nkadj) that minimizes this error. Methods: The nkexact value was determined by obtaining differences (ΔPc) between keratometric corneal power (Pk) and Gaussian corneal power ((Equation is included in full-text article.)) equal to 0. The nkexact was defined as the value associated with an equivalent difference in the magnitude of ΔPc for extreme values of posterior corneal radius (r2c) for each anterior corneal radius value (r1c). This nkadj was considered for the calculation of the adjusted corneal power (Pkadj). Values of r1c ∈ (4.2, 8.5) mm and r2c ∈ (3.1, 8.2) mm were considered. Differences of True Net Power with (Equation is included in full-text article.), Pkadj, and Pk(1.3375) were calculated in a clinical sample of 44 eyes with keratoconus. Results: nkexact ranged from 1.3153 to 1.3396 and nkadj from 1.3190 to 1.3339 depending on the eye model analyzed. All the nkadj values adjusted perfectly to 8 linear algorithms. Differences between Pkadj and (Equation is included in full-text article.)did not exceed ±0.7 D (Diopter). Clinically, nk = 1.3375 was not valid in any case. Pkadjand True Net Power and Pk(1.3375) and Pkadj were statistically different (P 0.01), whereas no differences were found between (Equation is included in full-text article.)and Pkadj (P 0.01). Conclusions: The use of a single value of nk for the calculation of the total corneal power in keratoconus has been shown to be imprecise, leading to inaccuracies in the detection and classification of this corneal condition. Furthermore, our study shows the relevance of corneal thickness in corneal power calculations in keratoconus.
机译:目的:本研究的目的是获得角膜曲率指数(nkexact)的准确值,并在临床上验证使该误差最小化的可变角膜曲率指数(nkadj)。方法:通过获得等于0的角膜角膜屈光度(Pk)和高斯角膜屈光度((方程式包含在全文中。))之间的差(ΔPc)来确定nkexact值。nkexact定义为与对于每个前角膜半径值(r1c),后角膜半径的最大值(r2c)的ΔPc大小相等。考虑该nkadj用于计算调整后的角膜屈光力(Pkadj)。考虑了r1c∈(4.2,8.5)mm和r2c∈(3.1,8.2)mm的值。在圆锥角膜的44眼临床样本中计算了True Net Power与(方程包括在全文中。),Pkadj和Pk(1.3375)之间的差异。结果:根据所分析的眼睛模型,nkexact的范围为1.3153至1.3396,nkadj的范围为1.3190至1.3339。所有nkadj值均已完美调整为8种线性算法。 Pkadj与(等式包含在全文中)之间的差异不超过±0.7 D(屈光度)。临床上,nk = 1.3375在任何情况下均无效。 Pkadjand的True Net Power和Pk(1.3375)和Pkadj在统计上是不同的(P <0.01),而Pkadj(在全文中包括了方程)和Pkadj(P> 0.01)之间没有发现差异。结论:使用nk的单个值来计算圆锥角膜的总角膜屈光力是不精确的,导致这种角膜病的检测和分类不准确。此外,我们的研究显示了圆锥角膜中角膜厚度与角膜屈光力计算的相关性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号