Assessing the Reproducibility of Quantitative In Vivo Confocal Microscopy of Corneal Nerves in Different Corneal Locations

机译:评估不同角膜位置的角膜神经定量共聚焦显微镜的可重复性

获取原文
获取原文并翻译 | 示例
           

摘要

To evaluate the reproducibility of in vivo confocal microscopy for quantitative corneal nerve analysis in different corneal locations. Methods: Corneal confocal microscopy was performed on 10 healthy participants, and the corneal nerve fiber length, corneal nerve fiber density, corneal nerve branch density, and tortuosity coefficient were measured at 5 predetermined locations for only the right eye. Bland-Altman plots, intraclass correlation coefficient (ICC), and coefficient of variation of all 4 corneal nerve measurements were compared between 2 visits and between readers to assess reproducibility. Two technicians performed a masked analysis of images from both visits. Results: Ten participants with a mean age of 31.3 +-2.8 years were imaged at 2 different time points separated by a mean of 4.3 +-4.3 weeks. The interobserver agreements were better than the intervisit agreements for all the 4 corneal nerve measurements as evaluated using Bland-Altman plots. The intervisit ICC ranged from 0.13 to 0.45, and the interobserver ICC ranged from 0.55 to 0.94. The differences between observers and the differences between sessions were not statistically different among all the 5 locations (P> 0.1) for each corneal nerve measurement. Conclusions: Single confocal images have poor reliability for any of the 4 corneal nerve measurements, and there is no single location on the cornea that has improved reproducibility. Averaging 5 images, from different locations, improves the reproducibility and is essential for obtaining clinically meaningful data.
机译:为了评估体内共聚焦显微镜在不同角膜位置定量角膜神经分析的可重复性。方法:对10名健康受试者进行了角膜共聚焦显微镜检查,仅在右眼的5个预定位置测量了角膜神经纤维长度,角膜神经纤维密度,角膜神经分支密度和曲折系数。比较两次访问之间以及读者之间的Bland-Altman图,组内相关系数(ICC)和所有4种角膜神经测量值的变异系数,以评估可重复性。两名技术人员对两次访问的图像进行了蒙版分析。结果:十个平均年龄为31.3±-2.8岁的参与者在两个不同的时间点成像,平均间隔为4.3±4.3周。使用Bland-Altman图评估的所有4个角膜神经测量结果,观察者间的一致性优于观察间的一致性。观察者间ICC范围从0.13到0.45,观察者间ICC范围从0.55到0.94。每次角膜神经测量的所有5个位置之间,观察者之间的差异和会话之间的差异均无统计学差异(P> 0.1)。结论:对于4个角膜神经测量中的任何一个,单个共聚焦图像的可靠性都较差,并且在角膜上没有单个位置可提高再现性。对来自不同位置的5张图像进行平均,可提高重现性,并且对于获得具有临床意义的数据至关重要。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号