首页> 外文期刊>Cornea >Sutureless fixation of amniotic membrane patch as a therapeutic contact lens by using a polymethyl methacrylate ring and fibrin sealant in a rabbit model.
【24h】

Sutureless fixation of amniotic membrane patch as a therapeutic contact lens by using a polymethyl methacrylate ring and fibrin sealant in a rabbit model.

机译:通过在兔模型中使用聚甲基丙烯酸甲酯环和血纤蛋白密封剂,无缝固定羊膜贴片作为治疗性隐形眼镜。

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

PURPOSE: To introduce and evaluate a sutureless technique by using a polymethyl methacrylate (PMMA) ring and fibrin sealant to fix an amniotic membrane (AM) patch on the ocular surface as a therapeutic contact lens in a rabbit model. METHODS: PMMA rings were fabricated by duplicating an impression of a rabbit conjunctival fornix. The central cornea of the left eye in 16 rabbits was deepithelialized (diameter = 10 mm). A human AM patch was fixed to the ocular surface by using either a PMMA ring and fibrin sealant or interrupted 10-0 nylon sutures. The fibrin sealant was used to create the PMMA ring-AM complex but not to attach the AM/PMMA ring to the ocular surface. The rabbits were followed up with slit-lamp examination and fluorescein staining for 7 days. Reepithelialization and complications were recorded. RESULTS: The corneal epithelial defect was recovered in each rabbit of both groups after 5 days. In the sutureless group, all membranes remained in place and intact during the follow-up period. Oneeye was noted to have a partial conjunctival epithelial defect caused by exposure to the PMMA ring. In contrast, >50% of rabbits in the interrupted suture group exhibited complications including conjunctival edema, suture loosening, patch detachment, bleeding, and conjunctival epithelial defects. CONCLUSIONS: The sutureless technique that uses a PMMA ring and fibrin sealant for AM patch placement has a lower incidence of complications than the interrupted suture method. This sutureless technique may promote increased clinical use of AM patch by alleviating patients' pain and shortening surgical time.
机译:目的:通过在兔模型中使用聚甲基丙烯酸甲酯(PMMA)环和血纤蛋白密封剂将羊膜(AM)贴片固定在眼表上作为治疗性隐形眼镜,来介绍和评估无缝合技术。方法:通过复制兔子结膜穹隆的印模来制作PMMA环。 16只兔子的左眼中央角膜被深层上皮化(直径= 10 mm)。通过使用PMMA环和血纤蛋白密封剂或间断的10-0尼龙缝线将人AM贴片固定在眼表上。纤维蛋白密封剂用于产生PMMA环-AM复合物,但不将AM / PMMA环连接至眼表。对兔子进行裂隙灯检查和荧光素染色7天。记录再上皮形成和并发症。结果:术后5d,两组每只兔角膜上皮缺损均恢复。在无缝合组中,在随访期间所有膜均保持原位并保持完整。据指出,单眼由于暴露于PMMA环而具有部分结膜上皮缺损。相反,在间断缝合组中,> 50%的兔子表现出并发症,包括结膜水肿,缝合线松弛,斑块脱落,出血和结膜上皮缺损。结论:采用PMMA环和纤维蛋白密封剂进行AM斑块贴片的无缝合技术比间断缝合法的并发症发生率更低。这种无缝合技术可通过减轻患者的痛苦并缩短手术时间来促进AM贴片的临床使用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号