Comparison and evaluation of central corneal thickness using 2 new noncontact specular microscopes and conventional pachymetry devices

机译:使用2种新型非接触式镜面显微镜和常规测厚仪比较和评估中央角膜厚度

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Purpose: The aim of this study was to evaluate the repeatability of central corneal thickness (CCT) measurements in normal eyes using 2 new noncontact specular microscopes (NCSMs) EM-3000 (Tomey, Japan) and SP-02 (CSO, Italy) and to compare the results with those obtained from an SP-3000P NCSM (Topcon, Japan) and ultrasound pachymetry (USP). Methods: Seventy subjects were enrolled in a prospective study. A single experienced ophthalmologist performed tests with each of the 4 instruments. Measurements were obtained in the right eye during the same session. The testing sequence of the NCSM was randomly selected. After performing noncontact examinations, the USP was performed to derive the CCT measurements. Intraoperator repeatability was analyzed using within-subject coefficient of variation and intraclass correlation coefficients. The agreement between NCSMs or NCSM and USP was assessed with Bland-Altman plots and 95% limits of agreement (LoA). Results: The mean CCT values measured by SP-3000P, EM-3000, SP-02, and USP were 513.66 ± 33.14 μm, 529.12 ± 33.22 μm, 549.06 ± 40.27 μm, and 539.01 ± 35.73 μm, respectively. All coefficients of variation were <1.3%, and the intraclass correlation coefficients were >0.95. There were statistically significant differences between any 2 devices as determined by CCT measurements. The mean difference between paired comparisons was >9 μm. The 95% LoA ranges were broad, and the greatest 95% LoA was found to exist between SP-3000P and SP-02. Conclusions: The new NCSMs and USP all show a high intraoperator repeatability for CCT measurements in normal eyes. However, interdevice agreement was poor and prevented the comparison of CCT measurements taken with different instruments.
机译:目的:本研究的目的是使用2台新的非接触式镜面显微镜(NCSM)EM-3000(日本托米)和SP-02(意大利的CSO)评估正常眼睛中中央角膜厚度(CCT)测量的可重复性,并将结果与从SP-3000P NCSM(日本Topcon)和超声测厚法(USP)获得的结果进行比较。方法:70名受试者参加了一项前瞻性研究。一名经验丰富的眼科医生对这4种仪器进行了测试。在同一疗程中右眼获得了测量值。 NCSM的测试顺序是随机选择的。进行非接触式检查后,执行USP以得出CCT测量值。使用受试者内部变异系数和组内相关系数分析术中重复性。 NCSM或NCSM与USP之间的协议是通过Bland-Altman图和95%的协议限制(LoA)进行评估的。结果:通过SP-3000P,EM-3000,SP-02和USP测量的平均CCT值分别为513.66±33.14μm,529.12±33.22μm,549.06±40.27μm和539.01±35.73μm。所有变异系数均<1.3%,组内相关系数均> 0.95。通过CCT测量确定的任何两个设备之间在统计学上都有显着差异。配对比较之间的平均差异> 9μm。 95%的LoA范围很广,发现最大的95%LoA存在于SP-3000P和SP-02之间。结论:新的NCSM和USP在正常眼睛中进行CCT测量时均显示出较高的术中可重复性。但是,设备间的一致性差,并且无法比较使用不同仪器进行的CCT测量。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号