In order to research the AC loss characteristics of a multi-layered conductor and a shield in a high temperature superconductor (HTS) cable, we prepared two short cable samples, which are the same as the 22.9 kV/50 MVA HTS-cable installed at Gochang test yard of Korea Electric Power Corporation, and attached voltage-leads to both the conductor and the shield. To investigate the effect of transport period on their AC losses, we also applied current with the same magnitude and opposite direction to the conductor and the shield from a few cycles to several minutes. The tests show that the AC loss measured from the lead attached to the shield (shield-lead) is constant regardless of transport period. But the measured loss from the lead attached to the conductor (conductorlead) is greatly dependent on transport period. It seems to be caused by difficulty in heat transfer to the surrounding coolant due to thick insulator around the conductor. As transport period becomes longer, the conductor's temperature rises and thus the AC loss measured from the conductor-lead increases. In addition, the measured loss from the conductor-lead is 1.5 times larger than that from the shield-lead, particularly for the transport period of a few cycles.
机译:为了研究高温超导体(HTS)电缆中多层导体和屏蔽层的交流损耗特性,我们准备了两个短电缆样本,它们与安装在22.9 kV / 50 MVA HTS电缆上的相同韩国电力公司高昌试验场,并在导体和屏蔽层上均连接了电压导线。为了研究传输周期对其交流电损耗的影响,我们还以相同的幅度和相反的方向将电流施加到导体和屏蔽层,周期为数分钟至数分钟。测试表明,无论运输时间长短,从连接到屏蔽层的导线(屏蔽线)测得的交流损耗都是恒定的。但是,从附着到导体的导线(导体导线)上测得的损耗在很大程度上取决于传输时间。这似乎是由于导体周围的绝缘层较厚而难以将热量传递到周围的冷却液中引起的。随着运输时间的延长,导体的温度升高,因此从导体引线测得的交流损耗增加。另外,从导体导线测得的损耗比从屏蔽导线测得的损耗大1.5倍,特别是在几个周期的传输时间内。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号