首页> 外文期刊>Spectrochimica acta, Part A. Molecular and biomolecular spectroscopy >Comparison of two methods for selegiline determination: A flow-injection chemiluminescence method using cadmium sulfide quantum dots and corona discharge ion mobility spectrometry
【24h】

Comparison of two methods for selegiline determination: A flow-injection chemiluminescence method using cadmium sulfide quantum dots and corona discharge ion mobility spectrometry

机译:两种司来吉兰测定方法的比较:使用硫化镉量子点和电晕放电离子迁移谱法的流动注射化学发光法

获取原文
获取原文并翻译 | 示例
           

摘要

Two analytical approaches including chemiluminescence (CL) and corona discharge ionization ion mobility spectrometry (CD-IMS) were developed for sensitive determination of selegiline (SG). We found that the CL intensity of the KMnO4-Na2S2O3 CL system was significantly enhanced in the presence of L-cysteine capped CdS quantum dots (QDs). A possible CL mechanism for this CL reaction is proposed. In the presence of SG, the enhanced CL system was inhibited. Based on this inhibition, a simple and sensitive flow-injection CL method was proposed for the determination of SG. Under optimum experimental conditions, the decreased CL intensity was proportional to SG concentration in the range of 0.01 to 30.0 mg L-1. The detection limit (3 sigma) was 0.004 mg L-1. Also, SG was determined using CD-IMS, and under optimum conditions of CD-IMS, calibration curves were linear in the range of 0.15 to 42.0 mg L-1, with a detection limit (3 sigma) of 0.03 mg L-1. The precision of the two methods was calculated by analyzing samples containing 5.0 mg L-1 of SG (n = 11). The relative standard deviations (RSDs%) of the flow-injection CL and CD-IMS methods are 2.17% and 3.83%, respectively. The proposed CL system exhibits a higher sensitivity and precision than the CD-IMS method for the determination of SG. (C) 2015 Elsevier B.V. All rights reserved.
机译:开发了两种分析方法,包括化学发光法(CL)和电晕放电电离离子迁移谱法(CD-IMS),用于灵敏测定司来吉兰(SG)。我们发现,在存在L-半胱氨酸帽的CdS量子点(QDs)的情况下,KMnO4-Na2S2O3 CL系统的CL强度显着增强。提出了该CL反应的可能的CL机理。在SG存在下,增强的CL系统被抑制。基于这种抑制作用,提出了一种简单而灵敏的流动注射CL法测定SG。在最佳实验条件下,降低的CL强度与SG浓度成正比,范围为0.01至30.0 mg L-1。检出限(3 sigma)为0.004 mg L-1。同样,使用CD-IMS测定SG,在CD-IMS的最佳条件下,校正曲线在0.15至42.0 mg L-1的范围内呈线性,检出限(3σ)为0.03 mg L-1。通过分析包含5.0 mg L-1 SG(n = 11)的样品来计算这两种方法的精度。流动注射CL和CD-IMS方法的相对标准偏差(RSDs%)分别为2.17%和3.83%。所提出的CL系统比用于确定SG的CD-IMS方法具有更高的灵敏度和精度。 (C)2015 Elsevier B.V.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号