...
首页> 外文期刊>RSC Advances >Durable porous polyaniline supported ionic liquid coating for the highly effective solid phase microextraction of trace fatty alcohols in drinks
【24h】

Durable porous polyaniline supported ionic liquid coating for the highly effective solid phase microextraction of trace fatty alcohols in drinks

机译:耐用的多孔聚苯胺负载型离子液体涂料,用于饮料中痕量脂肪醇的高效固相微萃取

获取原文
获取原文并翻译 | 示例

摘要

A polyaniline (PANI)-ionic liquid (IL) based solid phase microextraction (SPME) coating is presented. The porous PANI was electrodeposited on a stainless steel wire, and then it was coated with IL. The porous PANI could well immobilize IL, and the obtained hybrid coating could be used for more than 110-times of adsorption/desorption. The extraction efficiency of different ILs (i.e. 1-butyl-3-methylimidazolium hexafluorophosphate, 1-butyl-3-methylimidazolium tetrafluoroborate, 1-octyl-3-methylimidazolium hexafluorophosphate and 1-(2-hydroxyethyl)-3-methylimidazolium bis(trifluoromethylsulfonyl)imide ([HOEMim]NTf2)) based coatings was compared for different analytes (i.e. benzene, aryl halide, phenolic, amine and fatty alcohol compounds). It was found that the PANI-[HOEMim]NTf2 coating exhibited quite high extraction efficiency for fatty alcohol compounds (i.e. 1-octanol, 1-nonanol, n-decanol, 1-undecanol and dodecanol). The dependence of the gas chromatograph peak areas of the analytes after SPME on their initial concentration in solution was investigated and the corresponding isothermal adsorption equation was displayed. After optimizing the conditions, linear detection ranges of 0.05 ng mL(-1) to 100 ng mL(-1) were obtained for different fatty alcohol compounds. The limits of detection were 0.0061-0.018 ng mL(-1). The relative standard deviations (RSD) of the peak area were below 8.4% for five repetitive extractions of solutions containing 25 ng mL(-1) fatty alcohol compounds. The proposed method was applied to the determination of the analytes in two tea drinks, and 57 ng mL(-1) of 1-nonanol was found in a jasmine tea sample, while 2.2 ng mL(-1) of 1-undecanol was found in a rock sugar lemon sample, but other analytes were below their detection limits. The recoveries for spiked fatty alcohols were 84.9-117.6%, and the RSDs were lower than 12.2%.
机译:介绍了一种基于聚苯胺(PANI)-离子液体(IL)的固相微萃取(SPME)涂料。将多孔PANI电沉积在不锈钢线上,然后用IL涂覆。多孔PANI能够很好地固定IL,所得的杂化涂层可用于110次以上的吸附/解吸。不同IL(即1-丁基-3-甲基咪唑六氟磷酸盐,1-丁基-3-甲基咪唑四氟硼酸盐,1-辛基-3-甲基咪唑六氟磷酸盐和1-(2-羟乙基)-3-甲基咪唑双(三氟甲基磺酰基)的提取效率比较了基于酰亚胺([HOEMim] NTf2)的涂层的不同分析物(即苯,芳基卤化物,酚,胺和脂肪醇化合物)。发现PANI- [HOEMim] NTf2涂层表现出对脂肪醇化合物(即1-辛醇,1-壬醇,正癸醇,1-十一烷醇和十二烷醇)的相当高的提取效率。研究了SPME后分析物的气相色谱峰面积与溶液中初始浓度的关系,并显示了相应的等温吸附方程。优化条件后,对于不同的脂肪醇化合物,线性检测范围为0.05 ng mL(-1)至100 ng mL(-1)。检测限为0.0061-0.018 ng mL(-1)。对于包含25 ng mL(-1)脂肪醇化合物的溶液的五次重复萃取,峰面积的相对标准偏差(RSD)低于8.4%。该方法用于两种茶饮料中分析物的测定,在茉莉花茶样品中发现57 ng mL(-1)的1-壬醇,而在2.2 ng mL(-1)的1-十一烷醇中在冰糖柠檬样品中检测,但其他分析物低于检测限。加标的脂肪醇的回收率为84.9-117.6%,RSD低于12.2%。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号