首页> 外文期刊>Electrochimica Acta >A disposable electrochemical immunosensor arrays using 4-channel screen-printed carbon electrode for simultaneous detection of Escherichia coli O157:H7 and Enterobacter sakazakii
【24h】

A disposable electrochemical immunosensor arrays using 4-channel screen-printed carbon electrode for simultaneous detection of Escherichia coli O157:H7 and Enterobacter sakazakii

机译:使用4通道丝网印刷碳电极的一次性电化学免疫传感器阵列,用于同时检测大肠杆菌O157:H7和阪崎肠杆菌

获取原文
获取原文并翻译 | 示例
           

摘要

An electrochemical immunosensor for Escherichia coli O157:H7 (E. coli O157:H7) and Enterobacter sakazakii (E. sakazakii) detection using carbon screen-printed low-density arrays is reported. The sensors were fabricated based on screen-printed carbon arrays containing four carbon working electrode, an integrated carbon counter electrodes and an integrated Ag/AgCl reference electrode. Multi-walled carbon nanotubes (MWCNTs)/sodium alginate (SA)/carboxymethyl chitosan (CMC) composite films were coated on all the working electrodes to enhance the sensitization of the electrode. Horseradish peroxidases (HRP) labeled antibodies of two bacteria were immobilize on different working electrode of the same screen-printed electrode respectively. The immobilization of MWCNTs, HRP labeled antibodies onto the screen-printed carbon electrodes was examined using atom force microscopy (AFM) and cyclic voltammetry (CV). The analytical performance of proposed immunosensor arrays toward E. sakazakii and E. coli O157:H7 was investigated by AFM and CV. Under optimal conditions, the linear range of E. sakazakii and E. coli O157:H7 were from 10~4 to 10~(10) cfu/ml, with a detection limit of 4.57 × 10~3 cfu/ml (S/N = 3) and 3.27 × 10~3 cfu/ml (S/N = 3), respectively. The specificity, reproducibility, stability and accuracy of the proposed immunosensor arrays were also evaluated. Two antibodies modified work electrodes were tested and compared in terms of sensitivity and ability to recognize different pathogenic biological species.
机译:报道了一种使用碳丝网印刷的低密度阵列检测大肠杆菌O157:H7(E. coli O157:H7)和阪崎肠杆菌(E. sakazakii)的电化学免疫传感器。这些传感器是基于包含四个碳工作电极,一个集成碳反电极和一个集成Ag / AgCl参比电极的丝网印刷碳阵列制造的。将多壁碳纳米管(MWCNT)/藻酸钠(SA)/羧甲基壳聚糖(CMC)复合膜涂覆在所有工作电极上,以增强电极的敏化性。将两种细菌的​​辣根过氧化物酶(HRP)标记的抗体分别固定在同一丝网印刷电极的不同工作电极上。使用原子力显微镜(AFM)和循环伏安法(CV)检查将MWCNTs,HRP标记的抗体固定在丝网印刷的碳电极上。通过AFM和CV研究了拟议的针对阪崎肠杆菌和大肠杆菌O157:H7的免疫传感器阵列的分析性能。在最佳条件下,阪崎肠杆菌和大肠杆菌O157:H7的线性范围为10〜4至10〜(10)cfu / ml,检出限为4.57×10〜3 cfu / ml(S / N = 3)和3.27×10〜3 cfu / ml(S / N = 3)。还评估了所提出的免疫传感器阵列的特异性,可重复性,稳定性和准确性。测试了两种经过抗体修饰的工作电极,并在敏感性和识别不同病原性生物种类的能力方面进行了比较。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号