...
首页> 外文期刊>Investigative ophthalmology & visual science >Ocular rigidity, ocular pulse amplitude, and pulsatile ocular blood flow: The effect of axial length
【24h】

Ocular rigidity, ocular pulse amplitude, and pulsatile ocular blood flow: The effect of axial length

机译:眼刚度,眼搏振幅和脉动眼血流量:轴向长度的影响

获取原文
获取原文并翻译 | 示例

摘要

PURPOSE. Previous studies have shown a negative correlation between axial length (AL) and pulsatile ocular blood flow (POBF). This relation has been questioned because of the possible confounding effect of ocular volume on ocular rigidity (OR). The purpose of this study was to investigate the relation between AL, as a surrogate parameter for ocular volume, and OR, ocular pulse amplitude (OPA), and POBF. METHODS. Eighty-eight cataract patients were enrolled in this study. A computer-controlled device comprising a microdosimetric pump and a pressure sensor was used intraoperatively. The system was connected to the anterior chamber and used to raise the intraocular pressure (IOP) from 15 to 40 mm Hg, by infusing the eye with a saline solution. After each infusion step, the IOP was continuously recorded for 2 seconds. Blood pressure and pulse rate were measured during the procedure. The OR coefficient was calculated from the pressure volume data. OPA and POBF were measured from pressure recordings. RESULTS. Median AL was 23.69 (interquartile range 3.53) mm. OR coefficient was 0.0218 (0.0053) μL-1. A negative correlation between the OR coefficient and AL (ρ = -0.641, P 0.001) was documented. Increasing AL was associated with decreased OPA (ρ =-0.637, P 0.001 and ρ =-0.690, P 0.001) and POBF (ρ =-0.207, P = 0.053 and ρ =-0.238, P = 0.028) at baseline and elevated IOP, respectively. CONCLUSIONS. Based on manometric data, increasing AL is associated with decreased OR, OPA, and POBF. These results suggest decreased pulsatility in high myopia and may have implications on ocular pulse studies and the pathophysiology of myopia.
机译:目的。先前的研究表明,轴向长度(AL)与搏动性眼部血流(POBF)之间呈负相关。由于眼容量可能对眼刚度(OR)产生混杂影响,因此人们对此关系提出了质疑。这项研究的目的是研究作为眼体积的替代参数的AL与OR,眼动幅度(OPA)和POBF之间的关系。方法。这项研究招募了88名白内障患者。术中使用了包括微剂量泵和压力传感器的计算机控制设备。该系统连接到前房,用于通过向眼睛中注入盐溶液将眼内压(IOP)从15 mm Hg升高到40 mm Hg。在每个输注步骤之后,连续记录IOP 2秒。在手术过程中测量血压和脉搏率。从压力体积数据计算OR系数。 OPA和POBF是从压力记录中测得的。结果。 AL中值为23.69 mm(四分位间距3.53)mm。 OR系数为0.0218(0.0053)μL-1。记录到OR系数与AL之间呈负相关(ρ= -0.641,P <0.001)。在基线和基线时,AL升高与OPA降低(ρ= -0.637,P <0.001和ρ= -0.690,P <0.001)和POBF(ρ= -0.207,P = 0.053和ρ= -0.238,P = 0.028)相关。眼压升高。结论。根据测压数据,AL升高与OR,OPA和POBF降低相关。这些结果表明高度近视眼的搏动性降低,并且可能对眼搏动研究和近视眼的病理生理有影响。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号