Topographical thickness of the epithelium and total cornea after overnight wear of reverse-geometry rigid contact lenses for myopia reduction.

机译:过夜佩戴反几何刚性隐形眼镜后,上皮和总角膜的地形厚度可减少近视。

获取原文
获取原文并翻译 | 示例
           

摘要

PURPOSE. To investigate topographical thickness changes of the epithelium and total cornea measured with optical coherence tomography (OCT) after overnight wear of rigid gas-permeable lenses. METHODS. Reverse geometry design CRT (Dk = 100) rigid (test) lenses (Paragon Vision Sciences, Mesa, AZ) were randomly fitted on one eye of each of 20 neophyte subjects (mean age, 24.6 +/- 2.7 years) and the other eye was fitted with an alignment tricurve rigid lens of the same material (control). Epithelial and total corneal thickness was measured at intervals of 10 degrees across a 10-mm zone of the horizontal meridian of the cornea, before and after overnight wear. Refractive error was measured with an autorefractor. These measurements were repeated 20 and 60 minutes and 3, 6, and 12 hours after lens removal. RESULTS. After one night of lens wear, myopia decreased in the test eye by 1.18 +/- 0.81 D, which was significantly different from baseline (P < 0.001). No significant change was found in the control eye. Twelve hours after removal, two thirds of the myopic reduction was still present. Different topographical swelling patterns were induced by the two lens designs, with greatest swelling occurring in the center with the control lens and in the midperiphery with the test lenses (polynomial regression: P < 0.005). Significantly greater central corneal swelling was found with the control lens than the test lens (6.9% +/- 3.1% vs. 4.9% +/- 2.0%, respectively, P = 0.006). The effect on epithelial thickness differed between lenses and depended on both position and time (F((48,912)) = 2.3; P = 0.000). Immediately after removal of the test lens, the central epithelium was 5.1% +/- 4.5% thinner than baseline, and all other locations (P < 0.005 post hoc tests) and the epithelium in the midperiphery showed significant thickening (1.9% on the temporal side and 2.4% on the nasal side, both P < 0.006 compared with the baseline). There were no significant changes in epithelial thickness with the control lens during the study period (post hoc tests: P > 0.05). CONCLUSIONS. The optical coherence tomograph is a sensitive instrument that can detect small changes in epithelial and corneal thickness across the entire cornea. Topographical thickness changes of the epithelium and total cornea induced by one night of reverse-geometry lens wear appear to be associated with the decrease of myopia.
机译:目的。为了研究在过夜佩戴硬质透气性镜片后用光学相干断层扫描(OCT)测量的上皮和总角膜的地形厚度变化。方法。反向几何设计CRT(Dk = 100)刚性(测试)镜片(Paragon Vision Sciences,Mesa,AZ)随机安装在20名初生受试者(平均年龄24.6 +/- 2.7岁)的每只眼睛中的另一只眼上装有相同材料的对准三曲线刚性镜片(对照)。在过夜佩戴前后,在角膜水平子午线的10毫米区域内以10度的间隔测量上皮和总角膜厚度。用自动验光仪测量屈光不正。摘除镜片后20、60分钟,3、6和12小时重复这些测量。结果。配镜一夜后,被测眼的近视度数降低了1.18 +/- 0.81 D,这与基线显着不同(P <0.001)。在对照眼中未发现明显变化。移除后十二小时,近视减少的三分之二仍然存在。两种镜片设计会导致不同的地形膨胀模式,最大的膨胀发生在控制镜片的中心和中周边的测试镜片(多项式回归:P <0.005)。与对照镜相比,与对照镜相比,角膜中央角膜肿胀明显更大(分别为6.9%+/- 3.1%和4.9%+/- 2.0%,P = 0.006)。晶状体之间对上皮厚度的影响不同,并且取决于位置和时间(F((48,912))= 2.3; P = 0.000)。取下测试晶状体后,中央上皮立即比基线薄5.1%+/- 4.5%,所有其他位置(事后检查后P <0.005)和中周上皮明显增厚(颞上皮1.9%侧和鼻侧占2.4%,与基线相比均P <0.006)。在研究期间,对照晶状体的上皮厚度没有显着变化(事后检验:P> 0.05)。结论。光学相干断层扫描仪是一种敏感的仪器,可以检测整个角膜上皮和角膜厚度的微小变化。一晚反向几何镜片配戴引起的上皮和总角膜的地形厚度变化似乎与近视的减少有关。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号