PURPOSE: We present a novel form of arc therapy: continuous arc rotation of the couch (C-ARC) and compare its dosimetry with three-dimensional conformal radiotherapy (3D-CRT), intensity-modulated radiotherapy (IMRT), and volumetric-modulated arc therapy (VMAT) for accelerated partial breast irradiation (APBI). C-ARC, like VMAT, uses a modulated beam aperture and dose rate, but with the couch, not the gantry, rotating. METHODS AND MATERIALS: Twelve patients previously treated with APBI using 3D-CRT were replanned with (1) C-ARC, (2) IMRT, and (3) VMAT. C-ARC plans were designed with one medial and one lateral arc through which the couch rotated while the gantry was held stationary at a tangent angle. Target dose coverage was normalized to the 3D-CRT plan. Comparative endpoints were dose to normal breast tissue, lungs, and heart and monitor units prescribed. RESULTS: Compared with 3D-CRT, C-ARC, IMRT, and VMAT all significantly reduced the ipsilateral breast V50% by the same amount (mean, 7.8%). Only C-ARC and IMRT plans significantly reduced the contralateral breast maximum dose, the ipsilateral lung V5Gy, and the heart V5%. C-ARC used on average 40%, 30%, and 10% fewer monitor units compared with 3D-CRT, IMRT, and VMAT, respectively. CONCLUSIONS: C-ARC provides improved dosimetry and treatment efficiency, which should reduce the risks of toxicity and secondary malignancy. Its tangent geometry avoids irradiation of critical structures that is unavoidable using the en face geometry of VMAT.
机译:目的:我们提出了一种新颖的电弧疗法形式:沙发连续电弧旋转(C-ARC),并将其剂量学与三维共形放射疗法(3D-CRT),强度调制放射疗法(IMRT)和体积调制放射疗法进行比较电弧疗法(VMAT)用于加速局部乳房照射(APBI)。像VMAT一样,C-ARC使用调制的光束孔径和剂量率,但在沙发而不是机架上旋转。方法和材料:12例先前接受过3D-CRT的APBI治疗的患者需要重新计划(1)C-ARC,(2)IMRT和(3)VMAT。 C-ARC平面设计成具有一个内侧和一个外侧弧线,在龙门架以切线角保持静止的同时,卧榻通过该弧形旋转。目标剂量覆盖范围已根据3D-CRT计划标准化。比较终点为正常乳腺组织,肺和心脏的剂量,并指定了监测单位。结果:与3D-CRT相比,C-ARC,IMRT和VMAT均将同侧乳房的V50%降低了相同量(平均值为7.8%)。只有C-ARC和IMRT计划显着降低了对侧乳房的最大剂量,同侧肺V5Gy和心脏V5%。与3D-CRT,IMRT和VMAT相比,C-ARC分别平均减少40%,30%和10%的监视器单元。结论:C-ARC可提高剂量学和治疗效率,从而降低毒性和继发性恶性肿瘤的风险。它的切线几何避免了使用VMAT的端面几何不可避免的关键结构的辐射。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号