Silica gel was chemically modified by a polymer containing thiol group and used as a solid phase extraction adsorbent for the determination of trace copper in drinking water samples by flame absorption spectrometry. The effects of pH, sample flow rate and volume, elution conditions and concomitant ions on the recovery of the analyte were investigated. The results showed that copper could be adsorbed at pH 6 and eluted by 4 mL HC1 solution (0.5 mol L~(-1)). Under the optimized conditions, the adsorption capacity of modified silica gel was found to be 3.7 mg g~(-1) for copper. The detection limit of the proposed method was 1,3 ng mL'for copper with an enrichment factor of 18.7. The analytical result for me certified reference water sampie(GBWE080081) was in a good agreement with the certified value. The proposed method has also been successfully applied to the determination of trace copper in boiled water, purified water and mineral water with the recoveries for spiked samples between 96 and 103 %.
机译:硅胶通过含硫醇基团的聚合物进行化学修饰,并用作固相萃取吸附剂,用于通过火焰吸收光谱法测定饮用水样品中的痕量铜。研究了pH,样品流速和体积,洗脱条件和伴随离子对分析物回收率的影响。结果表明,铜在pH为6时可以被吸附,并被4 mL HCl溶液(0.5 mol L〜(-1))洗脱。在最佳条件下,改性硅胶对铜的吸附容量为3.7 mg g〜(-1)。该方法的检出限为铜的1.3 ng mL',富集系数为18.7。经认证的参比水样(GBWE080081)的分析结果与认证值完全吻合。该方法已成功应用于沸水,纯净水和矿泉水中痕量铜的测定,加标样品的回收率在96%至103%之间。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号