A low-cost, broadband, astigmatism-corrected Czerny-Turner arrangement with a fixed plane grating is proposed. A wedge cylindrical lens is used to correct astigmatism over a broadband spectral range. The principle and method of astigmatism correction are described in detail. We compare the performance of this modified Czerny-Turner arrangement with that of the traditional Czerny-Turner arrangement by using a practical Czerny-Turner imaging spectrometer example.
机译:提出了一种具有固定平面光栅的低成本,宽带,经像散校正的Czerny-Turner装置。楔形柱面透镜用于校正宽带光谱范围内的像散。详细描述了像散校正的原理和方法。通过使用实际的Czerny-Turner成像光谱仪示例,我们将这种改进的Czerny-Turner装置的性能与传统Czerny-Turner装置的性能进行了比较。