A simple approach is proposed for quantifying the errors in measuring the Brillouin frequency shifts associated with stresses whose lengths are shorter than the pulse length. The smallest detectable Brillouin frequency shift is thus determined with respect to the size of the stressed sections and the frequency resolution. The lowest detectable frequency shift is found to be -42% of the Brillouin gain natural linewidth. A worst-case iso-error curve that associates the minimum frequency shift to the length of the stressed region is derived. A minimum resolvable frequency shift and minimum detectable stress length are defined with an approach based on a Rayleigh equivalent criterion. (c) 2005 Optical Society of America.
机译:提出了一种简单的方法来量化在测量布里渊频移中的误差,该误差与长度短于脉冲长度的应力有关。因此,相对于受力部分的大小和频率分辨率,确定了最小的可检测布里渊频移。发现最低的频移是布里渊增益自然线宽的-42%。得出了将最小频移与受力区域的长度相关联的最坏情况的等误差曲线。使用基于瑞利等效准则的方法定义了最小可分辨频移和最小可检测应力长度。 (c)2005年美国眼镜学会。