...
首页> 外文期刊>Analytical and bioanalytical chemistry >In-line coupling of single-drop microextraction with capillary electrophoresis-mass spectrometry
【24h】

In-line coupling of single-drop microextraction with capillary electrophoresis-mass spectrometry

机译:单滴微萃取与毛细管电泳质谱的在线耦合

获取原文
获取原文并翻译 | 示例
           

摘要

Single-drop microextraction (SDME) was in-line coupled with capillary electrophoresis-mass spectrometry to provide sample cleanup and enrichment simultaneously. Since there is no outlet vial in a conventional capillary electrophoresis-electrospray ionization-mass spectrometry (CE-ESI-MS) configuration, it is not easy to hang a single drop in the capillary inlet for extraction. We overcame the difficulty of coupling SDME and CE-MS by using a temporary outlet reservoir. Basic drugs such as methamphetamine, amphetamine, phenethylamine, methoxyphenamine, and mephentermine were extracted from a basic sample solution to an acidic acceptor drop covered with a thin octanol layer formed at the capillary inlet tip. Compared to the CE-MS method in the multiple reaction monitoring (MRM) mode, the in-line SDME-CE-MS/MS technique showed 130 similar to 150-fold enrichment in 10 min. The relative standard deviations (RSDs) of peak height ranged from 9 to 13 %. RSDs can be reduced from 4 to 6 % using mephentermine as an internal standard. We examined the pretreatment of sample with and without SDME from human urine under the full-scan mode, which confirmed that many metabolites were cleaned up by the selective extraction method of SDME. Even if the analytes from human urine were analyzed under the MRM mode used as a mass filter, there was an isobaric compound causing a disturbance to the analysis. However, in-line SDME-CE-MS/MS made it possible to perform a sample cleanup as well as sample enrichment. The research is extremely advantageous in that it is rapid, convenient, and highly sensitive for the analysis of biological samples using a commercially available instrument.
机译:单滴微萃取(SDME)在线联用毛细管电泳-质谱法,以同时提供样品净化和富集。由于在传统的毛细管电泳-电喷雾电离质谱(CE-ESI-MS)配置中没有出口小瓶,因此在毛细管入口中悬挂一滴进行萃取并不容易。我们克服了使用临时出口储液罐耦合SDME和CE-MS的困难。从碱性样品溶液中提取碱性药物(如甲基苯丙胺,苯丙胺,苯乙胺,甲氧基苯胺和美芬特敏)至酸性受体滴,该液滴由覆盖在毛细管入口尖端的辛醇薄层覆盖。与多反应监测(MRM)模式下的CE-MS方法相比,在线SDME-CE-MS / MS技术在10分钟内显示130倍的富集150倍。峰高的相对标准偏差(RSD)为9%至13%。使用美芬特明作为内标,RSD可以从4%降低到6%。我们在全扫描模式下检查了有或没有人尿的SDME样品的预处理,这证实了通过SDME的选择性提取方法可以清除许多代谢产物。即使在用作质量过滤器的MRM模式下分析了人类尿液中的分析物,也会存在等压化合物对分析造成干扰。但是,在线SDME-CE-MS / MS使得可以执行样品净化以及样品富集。该研究具有极大的优势,因为它对使用市售仪器进行的生物样品分析具有快速,方便和高度灵敏的特点。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号