A novel dual-function mixed-mode stationary phase based on poly(glycidyl methacrylate-co-ethylene dimethacrylate) microspheres was synthesized by thiol-ene click chemistry and characterized by infrared spectroscopy and elemental analysis. The new system displays both hydrophobic interaction chromatography (HIC) character in a high salt concentration mobile phase, and weak cation exchange (WCX) chromatography character in a low salt concentration mobile phase. It can be used to separate proteins in both ion-exchange chromatography (IEC) mode and HIC mode. The resolution and selectivity of the stationary phase were evaluated in both HIC mode and IEC mode using protein standards. In comparison with the conventional WCX and HIC columns, the results were satisfactory and acceptable. Protein mass and bioactivity recoveries of more than 96 % can be achieved in both HIC mode and IEC mode using this column. The results indicate that the novel dual-function mixed-mode column in many cases can replace the use of two individual WCX and HIC columns. In addition, the effects on protein separation of different ligand structures in the dual-function stationary phase and the pH of the mobile phase used were also investigated in detail. The results show that electrostatic interaction of the ligand with proteins must match the hydrophobicity of the ligand, which is an important factor to prepare the dual-function stationary phase. On the basis of this dual-function mixed-mode chromatography column, a new two-dimensional liquid chromatography technology with a single column system was also developed in this study, and was used to renature and purify recombinant human interferon-gamma from inclusion bodies. The mass recovery, purity, and specific bioactivity obtained for the purified recombinant human interferon-gamma were 87.2 %, 92.4 %, and 2.8 x 10(7) IU/mg, respectively, in IEC mode, and 83.4 %, 95.2 %, and 4.3 x 10(7) IU/mg, respectively, in HIC mode. The results indicate that the dual-function mixed-mode stationary phase prepared in this study may aid in the development of new two-dimensional liquid chromatography technology with a single column for intensive proteomic studies, and it may also find applications in recombinant protein drug production since it can save column costs and simplify the biotechnological processes.
机译:通过硫醇-烯点击化学合成了一种基于聚甲基丙烯酸缩水甘油酯-共聚二甲基丙烯酸乙二酯共聚物的新型双功能混合模式固定相,并通过红外光谱和元素分析对其进行了表征。新系统在高盐浓度流动相中既显示疏水相互作用色谱(HIC)特征,又在低盐浓度流动相中显示弱阳离子交换(WCX)色谱特征。它可以在离子交换色谱(IEC)模式和HIC模式下用于分离蛋白质。使用蛋白质标准品在HIC模式和IEC模式下评估固定相的分离度和选择性。与常规WCX和HIC色谱柱相比,结果令人满意且可以接受。使用该色谱柱在HIC模式和IEC模式下均可实现超过96%的蛋白质质量和生物活性回收率。结果表明,新型双功能混合模式色谱柱在许多情况下可以代替使用两个单独的WCX和HIC色谱柱。此外,还详细研究了双功能固定相中不同配体结构对蛋白质分离的影响以及所用流动相的pH。结果表明,配体与蛋白质的静电相互作用必须与配体的疏水性相匹配,这是制备双功能固定相的重要因素。在此双功能混合模式色谱柱的基础上,本研究还开发了一种具有单柱系统的新型二维液相色谱技术,并用于从包涵体中复性和纯化重组人干扰素-γ。在IEC模式下,纯化的重组人干扰素-γ的质量回收率,纯度和比生物活性分别为87.2%,92.4%和2.8 x 10(7)IU / mg,分别为83.4%,95.2%和在HIC模式下分别为4.3 x 10(7)IU / mg。结果表明,本研究中制备的双功能混合模式固定相可能有助于开发一种新型的二维液相色谱技术,该技术可以通过单个色谱柱进行深入的蛋白质组学研究,也可以在重组蛋白药物生产中找到应用因为它可以节省色谱柱成本并简化生物工艺流程。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号