首页> 外文期刊>Analytica chimica acta >In situ selective determination of methylmercury in river water by diffusive gradient in thin films technique (DGT) using baker's yeast (Saccharomyces cerevisiae) immobilized in agarose gel as binding phase
【24h】

In situ selective determination of methylmercury in river water by diffusive gradient in thin films technique (DGT) using baker's yeast (Saccharomyces cerevisiae) immobilized in agarose gel as binding phase

机译:以琼脂糖凝胶固定的面包酵母(Saccharomyces cerevisiae)为扩散相,通过薄膜扩散梯度技术(DGT)原位选择性测定河水中的甲基汞

获取原文
获取原文并翻译 | 示例
           

摘要

Saccharomyces cerevisiae immobilized in agarose gel as binding phase and polyacrylamide as diffusive layer in the diffusive gradient in thin films technique (DGT) was used for selective determination of methylmercury (MeHg). Deployment tests showed good linearity in mass uptake up to 48 h (3276 ng). When coupling the DGT technique with Cold Vapor Atomic Fluorescence Spectrometry, the method has a limit of detection of 0.44 ng L-1 (pre concentration factor of 11 for 48 h deployment). Diffusion coefficient of 7.03 +/- 0.77 x 10(-6) cm(2) s(-1) at 23 degrees C in polyacrylamide gel (pH = 5.5 and ionic strength = 0.05 mol L-1 NaCl) was obtained. Influence of ionic strength (from 0.0005 mol L-1 to 0.1 mol L-1 NaCl) and pH (from 3.5 to 8.5) on MeHg uptake were evaluated. For these range, recoveries of 84-105% and 84-98% were obtained for ionic strength and pH respectively. Potential interference due to presence of Cu, Fe, Mn, Zn was also assessed showing good recoveries (70-87%). The selectivity of the proposed approach was tested by deployments in solutions containing MeHg and Hg(II). Results obtained showed recoveries of 102-115 % for MeHg, while the uptake of Hg(II) was insignificant. The proposed approach was successfully employed for in situ measurements in the Negro River (Manaus-AM, Brazil). (C) 2015 Elsevier B.V. All rights reserved.
机译:以薄膜扩散梯度技术(DGT)固定在琼脂糖凝胶中固定为结合相的啤酒酵母和聚丙烯酰胺作为扩散层,用于甲基汞(MeHg)的选择性测定。展开测试显示,长达48小时(3276 ng)的质量吸收具有良好的线性。当将DGT技术与冷蒸气原子荧光光谱法结合使用时,该方法的检测限为0.44 ng L-1(部署48小时的预浓缩系数为11)。在23摄氏度下,聚丙烯酰胺凝胶(pH = 5.5和离子强度= 0.05 mol L-1 NaCl)中的扩散系数为7.03 +/- 0.77 x 10(-6)cm(2)s(-1)。评估了离子强度(0.0005 mol L-1至0.1 mol L-1 NaCl)和pH值(3.5至8.5)对MeHg吸收的影响。在这些范围内,离子强度和pH分别获得84-105%和84-98%的回收率。还评估了由于存在铜,铁,锰,锌引起的潜在干扰,显示出良好的回收率(70-87%)。通过在含MeHg和Hg(II)的溶液中进行部署,测试了所提出方法的选择性。所得结果表明,MeHg的回收率为102-115%,而Hg(II)的吸收微不足道。所提出的方法已成功地用于尼格罗河(巴西马瑙斯-AM)的原位测量。 (C)2015 Elsevier B.V.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号