The paper presents the first report on fabrication and application of a user friendly and mercury free electrochemical sensor, with the renewable bismuth bulk annular band working electrode (RBiABE), in stripping voltammetry (SV). The sensor body is partly filled with the internal electrolyte solution, in which the RBiABE is cleaned and activated before each measurement. Time of the RBiABE contact with the sample solution is precisely controlled. The usefulness of this sensor was tested by Ni(II) and Co(II) traces determination by means of differential pulse adsorptive stripping voltammetry (DP AdSV), after complexation with dimethylglyoxime (DMG) in ammonia buffer (pH 8.2). The experimental variables (composition of the supporting electrolyte, pre-concentration potential and time, potential of the RBiABE activation, and DP parameters), as well as possible interferences, were investigated. The linear calibration graphs for Ni(II) and Co(II), determined individually and together, in the range from 1 x 10(-8) to 70 x 10(-8) mol L-1 and from 1 x 10(-9) to 70 x 10(-9) mol L-1 respectively, were obtained. The calculated limit of detection (LOD), for 30 s of the accumulation time, was 3 x 10(-9) mol L-1 for Ni(II) in case of a single element's analysis, whereas the LOD was 5 x 10(-9) mol L-1 for Ni(II) and 3 x 10(-10) mol L-1 for Co(II), when both metal ions were measured together. The repeatability of the Ni(II) and Co(II) adsorptive stripping voltammetric signals obtained at the RBiABE were equal to 5.4% and 2.5%, respectively (n = 5). Finally, the proposed method was validated by determining Ni(II) and Co(II) in the certified reference waters (SPS-SW1 and SPS-SW2) with satisfactory results. (C) 2015 Elsevier B.V. All rights reserved.
机译:这篇论文提出了在溶出伏安法(SV)中使用可再生铋本体环形带工作电极(RBiABE)的用户友好型无汞电化学传感器的制造和应用的第一份报告。传感器主体部分填充有内部电解质溶液,其中RBiABE在每次测量之前均已清洁并激活。 RBiABE与样品溶液接触的时间得到精确控制。在氨缓冲液(pH 8.2)中与二甲基乙二肟(DMG)络合后,通过差分脉冲吸附溶出伏安法(DP AdSV)通过Ni(II)和Co(II)痕量测定测试了该传感器的实用性。研究了实验变量(支持电解质的组成,预浓缩电位和时间,RBiABE活化电位和DP参数)以及可能的干扰。 Ni(II)和Co(II)的线性校准图,分别从1 x 10(-8)到70 x 10(-8)mol L-1和1 x 10(-分别获得9)至70 x 10(-9)mol L-1。在单元素分析的情况下,对于累积时间30 s,Ni(II)的计算检出限(LOD)为3 x 10(-9)mol L-1(对于Ni(II)),而LOD为5 x 10(当同时测量两种金属离子时,对于Ni(II)为-9)mol L-1,对于Co(II)为3 x 10(-10)mol L-1。在RBiABE处获得的Ni(II)和Co(II)吸附溶出伏安信号的重复性分别等于5.4%和2.5%(n = 5)。最后,通过在认证参考水(SPS-SW1和SPS-SW2)中测定Ni(II)和Co(II)验证了该方法的有效性。 (C)2015 Elsevier B.V.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号