...
首页> 外文期刊>Analytica chimica acta >Use of benchtop exactive high resolution and high mass accuracy orbitrap mass spectrometer for screening in horse doping control
【24h】

Use of benchtop exactive high resolution and high mass accuracy orbitrap mass spectrometer for screening in horse doping control

机译:使用台式精确高分辨率和高质量高精度Orbitrap质谱仪进行马兴奋剂检查中的筛查

获取原文
获取原文并翻译 | 示例
           

摘要

Liquid chromatography-mass spectrometry (LC-MS) has been widely used in doping control laboratories over the last two decades. Currently, simple quadrupole, triple quadrupole and ion trap are the most commonly employed analyzers in toxicological analysis. Nevertheless, the main lack of these technologies is the restricted number of target compounds simultaneously screened without loss of sensitivity. In this article we present an innovative screening approach routinely applied in the French horse doping control laboratory based on high resolution (50000) and high mass accuracy (< 5 ppm) in full scan MS mode for more than 235 target analytes screened from an initial volume of 5 mL of urine. The sample preparation was classically founded on solid phase extraction by means of reverse phase C18 cartridges. LC-MS analyses were carried out on a Shimadzu binary HPLC pumps linked to a C18 Sunfire column associated with the high resolution exactive benchtop orbitrap mass spectrometer. This screening was performed alternatively in positive-negative ionization mode during the same run. Thus, the identification of compounds of interest was made using their exact mass in positive-negative ionization mode at their expected retention time. All data obtained were processed by Tox1D software (ThermoFisherScientific) which is able to identify a molecule by theoretical mass and retention time. In order to illustrate this innovative technology applied in our laboratory, sample preparation, validation data performed on 20 target compounds from 16 different horse urine samples, chromatograms and spectra will be discussed in this paper.
机译:在过去的二十年中,液相色谱-质谱法(LC-MS)已广泛用于掺杂控制实验室。当前,简单的四极杆,三重四极杆和离子阱是毒理学分析中最常用的分析仪。然而,这些技术的主要不足是在不损失灵敏度的情况下同时筛选的目标化合物数量有限。在本文中,我们提出了一种创新的筛选方法,该方法基于高分辨率(50000)和高质量准确度(<5 ppm)在全扫描MS模式下常规应用于法国马兴奋剂控制实验室,用于从初始体积中筛选出235种以上的目标分析物5毫升尿液。样品制备通常基于通过反相C18柱进行固相萃取而建立。 LC-MS分析是在Shimadzu二元HPLC泵上进行的,该泵与与高分辨率精密台式Orbitrap质谱仪关联的C18 Sunfire色谱柱连接。在相同的运行过程中,该筛选以正负电离模式进行。因此,在目标化合物的预期保留时间使用正负电离模式的精确质量进行目标化合物的鉴定。通过Tox1D软件(ThermoFisherScientific)处理获得的所有数据,该软件能够通过理论质量和保留时间识别分子。为了说明这种创新技术在我们实验室中的应用,本文将讨论样品制备,对来自16种不同马尿样品的20种目标化合物进行的验证数据,色谱图和光谱图。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号