首页> 外文期刊>Analytica chimica acta >Microtiterplate phosphate assay based on luminescence quenching of a terbium complex amenable to decay time detection
【24h】

Microtiterplate phosphate assay based on luminescence quenching of a terbium complex amenable to decay time detection

机译:基于ti合物的发光淬灭的微滴定板磷酸盐测定法,适用于衰减时间检测

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

We describe a terbium-ligand complex (TbL) for a microtiterplate assay for phosphate (P) in the 0.3-100 μmol L~(-1) range based on luminescence quenching. As the pH optimum is at neutral pH (7.4) the probe is quenched by both, primary (H2PO4~-) and secondary phosphate (HPO4~(2-)). The LOD is 110 nmol L~(-1). A Stern-Volmer study revealed that quenching is mostly static. Due to the ms-decay time of TbL, the first luminescence lifetime assay for phosphate could also be developed. The lifetime-based calibration plot is linear between 0.5 and 5 μmol L~(-1) of P. The effect of various surfactants on assay performance and a study on interferents are presented. The probe was successfully applied to determination of P in commercial plant fertilizers and validated against the molybdenum blue test. The probe is the most sensitive lanthanide-based probe for phosphate.
机译:我们描述了a-配体配合物(TbL),用于基于发光猝灭的0.3-100μmolL〜(-1)范围内的磷酸盐(P)微量滴定板测定。由于最适pH在中性pH(7.4)时,探针被伯磷酸酯(H2PO4-)和仲磷酸酯(HPO4-(2-))淬灭。 LOD为110 nmol L〜(-1)。斯特恩-沃尔默(Stern-Volmer)的一项研究表明,淬火通常是静态的。由于TbL的ms衰减时间,也可以开发磷酸盐的第一个发光寿命测定法。基于寿命的校准曲线在P的0.5至5μmolL〜(-1)之间呈线性关系。提出了各种表面活性剂对测定性能的影响以及对干扰物的研究。该探针已成功应用于商业化肥中磷的测定,并经过了钼蓝测试的验证。该探针是对磷酸盐最敏感的基于镧系元素的探针。