首页> 外文期刊>Analytica chimica acta >Comparison between triple quadrupole, time of flight and hybrid quadrupole time of flight analysers coupled to liquid chromatography for the detection of anabolic steroids in doping control analysis
【24h】

Comparison between triple quadrupole, time of flight and hybrid quadrupole time of flight analysers coupled to liquid chromatography for the detection of anabolic steroids in doping control analysis

机译:三重四极杆,飞行时间和混合四极杆飞行时间分析仪与液相色谱法在掺杂控制分析中用于检测合成代谢类固醇的比较

获取原文
获取原文并翻译 | 示例
           

摘要

Triple quadrupole (QqQ), time of flight (TOF) and quadrupole-time of flight (QTOF) analysers have been compared for the detection of anabolic steroids in human urine. Ten anabolic steroids were selected as model compounds based on their ionization and the presence of endogenous interferences/Both qualitative and quantitative analyses were evaluated. QqQ allowed for the detection of all analytes at the minimum required performance limit (MRPL) established by the World Anti-Doping Agency (between 2 and 10ng mL~(-1) in urine). TOF and QTOF approaches were not sensitive enough to detect some of the analytes (3'-hydroxy-stanozolol or the metabolites of boldenone and formebolone) at the established MRPL Although a suitable accuracy was obtained, the precision was unsatisfactory (RSD typically higher than 20%) for quantitative purposes irrespective of the analyser used. The methods were applied to 30 real samples declared positives either for the misuse of boldenone, stanozolol and/or methandienone. Most of the compounds were detected by every technique, howeveT QqQ was necessary for the detection of some metabolites in a few samples. Finally, the possibility to detect non-target steroids has been explored by the use of TOF and QTOF. The use of this approach revealed that the presence of boldenone and its metabolite in one sample was due to the intake of androsta-1,4,6-triene-3,17-dione. Additionally, the intake of methandienone was confirmed by the post-target detection of a long-term metabolite.
机译:对三重四极杆(QqQ),飞行时间(TOF)和四极杆飞行时间(QTOF)分析仪进行了比较,以检测人尿中的合成代谢类固醇。根据十种合成代谢类固醇的离子化作用,选择它们作为模型化合物,并对内源性干扰物的存在/定性和定量分析进行了评估。 QqQ能够以世界反兴奋剂机构规定的最低要求性能极限(MRPL)(尿液中2至10ng mL〜(-1)之间)检测所有分析物。在既定的MRPL下,TOF和QTOF方法灵敏度不足以检测某些分析物(3'-羟基-stanozolol或丁烯酮和甲酸甲酮的代谢物)尽管获得了合适的准确度,但精密度仍不令人满意(RSD通常高于20 %)用于定量目的,与使用的分析仪无关。将该方法应用于30个被宣布为阳性的真实样品,这些样品被误用了海地黄酮,康乃洛尔和/或二氢大麻酮。大多数化合物都是通过每种技术检测的,而QqQ对于检测少量样品中的某些代谢物是必需的。最后,已经通过使用TOF和QTOF探索了检测非目标类固醇的可能性。这种方法的使用表明,一个样品中存在双烯酮及其代谢产物是由于摄入了雄甾烯-1,4,6-三烯-3,17-二酮。另外,通过长期代谢物的靶后检测证实了甲氨蝶呤的摄入。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号