...
首页> 外文期刊>Analytica chimica acta >Rapid analysis of 21 antibiotics of multiple classes in municipal wastewater using ultra performance liquid chromatography-tandem mass spectrometry
【24h】

Rapid analysis of 21 antibiotics of multiple classes in municipal wastewater using ultra performance liquid chromatography-tandem mass spectrometry

机译:高效液相色谱-串联质谱法快速分析市政废水中的21种抗生素

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

In this study, solid phase extraction (SPE) and ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) were utilized to develop a rapid, sensitive and reliable method for trace analysis of 21 antibiotics belonging to 7 classes in influent and effluent of municipal wastewater treatment plant. Detection parameters for SPE preconcentration and UPLC-MS/MS analysis were optimized, including sample pH, eluant, mobile phase (solvent and formic acid concentration), column temperature, and flow rate. Under the optimal conditions, the recoveries for different antibiotics ranged from 60.5% to 109.7% and all analytes were detected within 10.0 min by UPLC-MS/MS. The validation study indicated that the method detection limits (MDLs) for the 21 antibiotics were from 0.3 to 60.0 ngL~(-1) for effluent, while higher MDLs (0.5-84.0 ng L~(-1)) for influent. Accuracy and precision for both within-run (-11.6 to 14.3% and 0.2 to 15.6%) and between-run tests (-7.2 to 8.7% and 1.9 to 16.4%) were acceptable. The analysis of influent and effluent samples of two municipal wastewater treatment plants in Hong Kong revealed the presence of 11 antibiotics, including ampicillin, cefalexin, sulfamethoxazole, sulfadiazine, norfloxacin, ciprofloxacin, ofloxacin, tetracycline, roxithromycin, erythromycin-H2O, and trimethoprim. Their concentration ranged from 3.5 to 720.0 ng L~(-1) in influent and from 2.1 to 556.4 ng L~(-1) in effluent.
机译:在这项研究中,固相萃取(SPE)和超高效液相色谱-串联质谱(UPLC-MS / MS)用于开发一种快速,灵敏和可靠的方法,用于痕量分析7种类别的21种抗生素。市政废水处理厂的废水。优化了SPE预浓缩和UPLC-MS / MS分析的检测参数,包括样品pH,洗脱液,流动相(溶剂和甲酸浓度),柱温和流速。在最佳条件下,不同抗生素的回收率在60.5%至109.7%之间,并且通过UPLC-MS / MS在10.0分钟内检测到所有分析物。验证性研究表明,对21种抗生素的方法检出限(MDLs)的范围从0.3到60.0 ngL〜(-1),而进水的MDL更高(0.5-84.0 ng L〜(-1))。批内(-11.6%至14.3%和0.2%至15.6%)和批间测试(-7.2%至8.7%和1.9%至16.4%)的准确性和精密度都可以接受。对香港两家市政污水处理厂的进水和出水样品进行的分析显示,存在11种抗生素,包括氨苄青霉素,头孢氨苄,磺胺甲恶唑,磺胺嘧啶,诺氟沙星,环丙沙星,氧氟沙星,四环素,罗红霉素,红霉素-H2O和甲氧苄啶。进水的浓度范围为3.5至720.0 ng L〜(-1),出水的浓度范围为2.1至556.4 ng L〜(-1)。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号