We report on the first detailed use of broadband cavity enhanced absorption spectroscopy (BBCEAS) as a detection system for immunoassay. A vertical R >= 0.99 optical cavity was integrated with a motorized XY stage, which functioned as a receptacle for 96-well microtiter plates. The custom-built cavity enhanced microplate reader was used to make measurements on a commercially available osteocalcin sandwich ELISA kit. A 30-fold increase in path length was obtained with a minimum detectable change in the absorption coefficient, alpha(min)(t), of 5.3 X 10(-5) cm(-1) Hz(-1/2). This corresponded to a 39-fold increase in the sensitivity of measurement when directly compared to measurements in a conventional microplate reader. Separate measurements of a standard STREP-HRP colorimetric reaction in microtiter plates of differing optical quality produced an increase in sensitivity of up to 115-fold compared to a conventional microplate reader. The sensitivity of the developed setup compared favorably with previous liquid-phase cavity enhanced studies and approaches the sensitivity of typical fluorometric ELISAs. It could benefit any biochemical test which uses single pass absorption as a detection method, through either the label free detection of biologically important molecules at lower concentrations or the reduction in the amount of expensive biochemicals needed for a particular test, leading to cheaper tests.
机译:我们报告了宽带腔增强吸收光谱法(BBCEAS)作为免疫测定检测系统的首次详细使用。垂直R> = 0.99光学腔与电动XY载物台集成在一起,该载物台用作96孔微量滴定板的容器。使用定制的腔增强微孔板读数器在市售骨钙蛋白夹心ELISA试剂盒上进行测量。路径长度增加了30倍,吸收系数α(min)(t)的最小可检测变化为5.3 X 10(-5)cm(-1)Hz(-1/2)。直接与常规酶标仪中的测量结果相比,这相当于测量灵敏度提高了39倍。与传统的酶标仪相比,在不同光学质量的微量滴定板中对标准STREP-HRP比色反应的单独测量产生的灵敏度提高了115倍。与以前的液相腔增强研究相比,开发的装置的灵敏度优越,并且接近典型的荧光ELISA的灵敏度。通过使用无标记的低浓度生物重要分子检测方法或减少特定检测所需的昂贵生化试剂数量,可以降低成本,从而使使用单程吸收作为检测方法的任何生化检测均受益。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号