首页> 外文期刊>Analytical chemistry >Detection Limits for Blood on Four Fabric Types Using Infrared Diffuse Reflection Spectroscopy in Mid- and Near-Infrared Spectral Windows
【24h】

Detection Limits for Blood on Four Fabric Types Using Infrared Diffuse Reflection Spectroscopy in Mid- and Near-Infrared Spectral Windows

机译:在中红外光谱窗口和近红外光谱窗口中使用红外漫反射光谱法对四种织物类型上的血液检测限

获取原文
获取原文并翻译 | 示例
           

摘要

Detection limits (DL) for blood on four fabric types were estimated for calibrations derived using partial least squares regression applied to infrared (IR) diffuse reflection spectra. Samples were prepared by dip-coating acrylic, cotton, nylon, and polyester fabrics from solutions of diluted rat blood. While DLs often appear in terms of dilution factor in the forensic community, mass percentage, coverage (mass per unit area), or film thickness are often more relevant when comparing experimental methods. These alternate DL units are related to one another and presented here. The best IR diffuse reflection DLs for blood on acrylic and cotton fabrics were in the mid-IR spectral window corresponding to the protein Amide I/II absorption bands. These DLs were dilution by a factor of 2300 (0.019% w/w blood solids) for acrylic and a factor of 610 (0.055% w/w blood solids) for cotton. The best DL for blood on polyester was found in the mid-IR spectral window corresponding to the protein Amide A absorption band at dilution by a factor of 900 (0.034% w/w blood solids). Because of the similarity between the IR spectra of blood solids and nylon fabrics, no satisfactory IR DLs were determined for the calibration of blood on nylon. We compare our values to DLs reported for blood detection using the standard luminol method. The most commonly reported luminol DLs are of the order of 1000-fold dilution, which we estimate are a factor of 2-7 lower than our reported IR DLs on a coverage basis
机译:通过使用应用于红外(IR)漫反射光谱的偏最小二乘回归得出的校准值,估算出四种织物上血液的检出限(DL)。通过从稀释的大鼠血液溶液中浸涂丙烯酸,棉,尼龙和聚酯织物来制备样品。虽然法医鉴定法常常以稀释因子的形式出现,但在比较实验方法时,质量百分比,覆盖率(单位面积质量)或膜厚度通常更为相关。这些备用DL单元彼此相关,并在此处显示。丙烯酸和棉织物上血液的最佳IR漫反射DL在与蛋白Amide I / II吸收带相对应的中红外光谱窗口中。对于丙烯酸,将这些DLs稀释至2300倍(血固形物,0.019%w / w),对于棉花,将其稀释至610倍(血固形物,0.055%w / w)。在中红外光谱窗口中找到了最佳的聚酯血液DL,对应于蛋白质Amide A吸收带,稀释了900倍(0.034%w / w血固形物)。由于血液固体和尼龙织物的红外光谱之间相似,因此无法确定令人满意的IR DL用于校准尼龙上的血液。我们将我们的值与报告的使用标准鲁米诺方法进行血液检测的DL进行比较。最常报告的鲁米诺DL约为稀释1000倍,我们估计其覆盖率比报告的IR DL低2-7倍

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号