A novel paper spray cartridge with an integrated solid phase extraction (SPE) column is described. The cartridge performs extraction and pre-concentration, as well as sample ionization by paper spray, from complex samples such as plasma. The cartridge allows for selective enrichment of target molecules from larger sample volumes and removal of the matrix, which significantly improved the signal intensity of target compounds in plasma samples by paper spray ionization. Detection limits, quantitative performance, recovery, ionization suppression, and the effects of sample volume were evaluated for five drugs: carbamazepine, atenolol, sulfamethazine, diazepam, and alprazolam. Compared with direct paper spray analysis of dried plasma spots, paper spray analysis using the integrated solid phase extraction improved the detection limits significantly by a factor of 14-70, depending on the drug. The improvement in detection limits was, in large part, due to the capability of analyzing larger sample volumes. In addition, ionization suppression was found to be lower and recovery was higher for paper spray with integrated SPE, as compared to direct paper spray analysis. By spiking an isotopically labeled internal standard into the plasma sample, a linear calibration curve for the drugs was obtained from the limit of detection (LOD) to 1 mu g/mL, indicating that this method can be used for quantitative analysis. The paper spray cartridge with integrated SPE could prove valuable for analytes that ionize poorly, in applications where lower detection limits are required, or on portable mass spectrometers. The improved performance comes at the cost of requiring a more complex paper spray cartridge and requiring larger sample volumes than those used in typical direct paper spray ionization.
机译:描述了一种具有集成固相萃取(SPE)柱的新型纸张喷雾器。该盒可从复杂的样品(例如血浆)中进行提取和预浓缩,以及通过纸喷雾进行样品电离。该弹药筒可从较大的样品量中选择性富集目标分子,并去除基质,从而通过纸喷雾电离显着改善了血浆样品中目标化合物的信号强度。对五种药物:卡马西平,阿替洛尔,磺胺二甲嘧啶,地西epa和阿普唑仑评估了检出限,定量性能,回收率,电离抑制和样品量的影响。与直接对干燥的血浆斑点进行纸喷雾分析相比,使用集成固相萃取进行纸喷雾分析可将检测限显着提高14-70倍,具体取决于药物。检出限的提高很大程度上归因于分析较大样品量的能力。此外,与直接纸雾分析相比,发现采用集成SPE的纸雾的电离抑制作用更低,回收率更高。通过将同位素标记的内标加标到血浆样品中,药物的线性校准曲线从检测限(LOD)达到1μg / mL,表明该方法可用于定量分析。带有集成SPE的纸质喷雾盒对于需要较低检测限的应用或便携式质谱仪而言,对于离子化较差的分析物而言,可能会很有价值。改善性能的代价是需要比常规直接纸雾化电离中使用的纸匣更复杂和需要更大的样品量。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号